IBM Ricoh FB750 manual Scanner Operation, Windows

Page 40

mode is usually done in the CMOS/BIOS setup (usually accessed while your computer is booting up). Consult the documentation that came with your computer for specific information on how to access your CMOS/BIOS and how to change the parallel port mode. The following directions may not apply directly to your CMOS/BIOS setup. Change ONLY the parallel port mode. Making other changes in your CMOS/BIOS could render your computer inoperable.

a)Shut Down your computer and restart it. While it is beginning to start-up, press the Delete key (may also be F1, F2, or some other key sequence depending on your comoputer, consult your computer manual) to go to the Setup Menu. There may be a message on your screen while your computer is starting that will tell you which key to press to go into the CMOS/BIOS.

b)Locate the Parallel Port option. This may be in a section titled Peripherals or Advanced or just on a second page. The parallel port option might also include things such as LPT1 or LPT2 and the address and IRQ.

c)Consult the on screen directions and change the MODE to EPP or ECP (preferred) or SPP. If there is a Standard or LPT mode, this is likely to equate to SPP. If you have no other modes, set it to this.

d)Change ONLY the parallel port mode. Making other changes in your CMOS/BIOS could render your computer inoperable.

e)Save changes and exit.

Scanner Operation

There is nothing in the selection box when I go to select source. Or I got an error message when installing the scanner driver (or application software).

Situation & Solution: If there are other programs running while you are installing the driver, it may not completely install, even though you got the message the installation was successful. You need to ensure there are no programs running in the background when you install the CD.

Windows 95:

1.With your desktop clear, press the Ctrl, the Alt and the Delete keys at the same time (Ctl+Alt+Del). This will bring up a Close Programs window. Everything listed in this window is a running program. Explorer is the Windows 95 desktop, you cannot close this program. Systray is the taskbar and time listing in generally in the lower right hand corner of your screen, you also cannot close this program (some systems do not list this program in the Close Program window). All other programs can be closed one at a time.

2.Highlight a program then click on End Task. The Close Program window will disappear, but

pressing Ctl+Alt+Del will bring it back up. This will only close these programs until the next time you boot your computer. All of these programs are generally set up to run as soon as you start your computer or boot up Windows.

3.When only Explorer and Systray are listed in the Close Programs window, click on Cancel.

4.Try to install the driver once more following the instructions found in the Quick Start Guide or in this manual (Scanner Driver and Application Software Installation).

Note: In Windows 95, you can also install the driver in Safe Mode. Copy the installation files into a temporary directory before shutdown and reboot into Safe Mode, then install from the temporary directory.

40

Image 40
Contents ImageReader PowerScan User’s Guide Model FB750Document Warranty Product WarrantyTrademarks CopyrightTable of Contents Maintenance TroubleshootingSpecifications Limited WarrantyWelcome IntroductionUser’s Guide Bold/Italics What is TWAIN? AssistancePage Scanner Setup System RequirementsConnecting the Scanner to the Computer Package ContentsUnlocking the Scanner Connecting the Power Adapter to a Power Supply Connecting a Printer to the ScannerScanner Driver and Application Software Installation Installation ProgramStarting the Installation Program Type D\Setup.exe or D\Autorun.exeSetup Type Scanner DriverScanner Model Destination DirectoryInstalling files PC Compatibility InformationRestart Windows User InformationInfoCenter 32 Complete, installing Headliner PictureMall PictureFun! Windows 95, 98 or NT only File Associations InfoCenter LiteRegistration User Information Installation Options Installation Paths Adobe Acrobat ReaderUninstalling Scanner Operation Selecting a Source in Scanning ApplicationsStarting the Scan Document PlacementTwain User Interface, scanning controls Image Types and Scanning Modes Image TypeScan Mode ResolutionImage Control OriginalRecommended Scanning Resolution and Mode by Task FunctionSpecial Controls ScaleCustom Scale DescreenTool Bar Settings Menu BarHistogram/Tone Map FileScanning Buttons HelpPreview ZoomPreview Window ScanIncluded Applications and Reading the Software Manuals InfoCenter 32 and InfoCenter LitePictureFun! Windows 95, 98, or NT PictureMall When to Use Which Application InfoCenter Lite Applications Windows 3.1 orPage Precautions MaintenanceCleaning the Glass Frequently Asked Questions FAQ TroubleshootingSetup & Installation Get a scanner test fail error when I attempt to scan Scanner Operation WindowsWhen I go to scan, I get a cannot access Twain driver error Why do my scanning results seem dark? Color Grayscale Black and whitePrinter Setup and Operation What is the function of the pass-through port?Click Spooler Settings Select Print Directly to the Printer Bulletin Board Service BBS 408Technical Support Fax on demand 408Name Phone Number FCC Radio Frequency Interference Statement SpecificationsModel FB750 EC Declaration of Conformity According to EN45014Tips & Hints for Using Your Scanner AppendixClick Save As or Save Image As Saving to Floppy Diskettes or for Email Glossary of Imaging Terms Bios BBSCIS BPPCmos CPU CRTDMA ECPEPP HSV Isis IRQISP Mime MPEG-1MPEG-2 MPEG-3PAL PMTPOP3 RAMROM SecamSmtp SPPTwain VGAFile Formats JPG, Jpeg Info Limited Warranty Info Service Center Division Street Campbell, CA