Hand Held Products 3900, 3800 manual To Clear One or All Prefixes or Suffixes, Scan Add Suffix

Page 50

Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover or scan 9, 9 for all symbologies.

Step 4. Determine the hex value from the Decimal to Hex to ASCII Conversion Chart (page 4-6) for the prefix or suffix you wish to enter.

Step 5. Scan the 2 digit hex value from the Programming Chart inside the back cover.

Step 6. Repeat Steps 4 and 5 for every prefix or suffix character.

Step 7. To add the Code I.D., scan 5, C, 8, 0.

To add AIM I.D., scan 5, C, 8, 1.

To add a backslash (\), scan 5, C, 5, C.

Step 8. Scan Save to exit and save, or scan Discard to exit without saving.

Repeat Steps 1-6 to add a prefix or suffix for another symbology.

Example: Add a Suffix to a specific symbology

To send a CR (carriage return)Suffix for UPC only:

Step 1. Scan Add Suffix.

Step 2. Determine the 2 digit hex value from the Symbology Chart (page 4-5) for UPC.

Step 3. Scan 6, 3 from the Programming Chart (inside back cover).

Step 4. Determine the hex value from the Decimal to Hex to ASCII Conversion Chart (page 4-6) for the CR (carriage return).

Step 5. Scan 0, D from the Programming Chart (inside back cover). Step 6. Scan Save, or scan Discard to exit without saving.

To Clear One or All Prefixes or Suffixes:

You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted.

Step 1. Scan the Clear One Prefix or Clear One Suffix symbol.

Step 2. Determine the 2 digit Hex value from the Symbology Chart (page 4-5) for the symbology from which you want to clear the prefix or suffix.

Step 3. Scan the 2 digit hex value from the Programming Chart inside the back cover or scan 9, 9 for all symbologies.

Your change is automatically saved.

4 - 2

3800/3900 User’s Guide

Image 50
Contents User’s Guide Disclaimer Canadian Notice Statement of Agency ComplianceFCC Class B Compliance Statement TÜV Statement LED Safety StatementUL and cUL Statement TIC StatementTable of Contents Output Data Formatting Code 93 Message Length Check Digit Addenda Addenda Required Addenda Separator Cloning Maintenance Viii About This Manual Getting StartedTypical Applications for Unpacking the Scanner Or anScanner Identification Scanner Bottom ViewConnecting the Scanner When Powered by Host Keyboard Wedge For Specular Zone Mounting InformationPlug and Play Option Setting IBM 4683 Ports 5B, 9B, and 17 Interface Symbology Suffix USB Interface3800/3900 User’s Guide NCR Ocia Short Format 8 Bit Interface Symbology PrefixOcia Interface Nixdorf Ocia Interface SymbologyNCR Ocia Long Format 9 Bit Interface Serial Wedge3800/3900 User’s Guide 3800/3900 User’s Guide Terminal Interfaces Keyboard Wedge ConnectionTerminal ID Supported Terminals Terminal Models Terminal IDSupported Terminals Country Code Scan Keyboard CountryKeyboard Style Keyboard Modifiers 3800/3900 User’s Guide Serial Port Connection Baud Rate RS-232 Word Length Data Bits, Stop Bits, and Parity RS-232 Word Length Data Bits, Stop Bits, and Parity RS-232 Handshaking Wand Emulation ConnectionWand Emulation Transmission Rate Wand Emulation Polarity Wand Emulation IdleDelay Between Blocks Data Block SizeOverall Checksum Scan Rate Beeper VolumeOutput Reduce Quiet Zone Beeper ToneScan Voting Reread Delay Good Read Delay Trigger ModeSerial Trigger Time Out 3800/3900 User’s Guide Prefix/Suffix Overview Scan the Add Prefix or Add Suffix symbolData Editing Points to Keep In MindScan Add Suffix Scan the Clear One Prefix or Clear One Suffix symbolTo Clear One or All Prefixes or Suffixes To Add a Carriage Return Suffix to all Symbologies Prefix Selections Suffix SelectionsHex Symbology Code Symbology ChartSymbology Code HexAscii Conversion Chart Code Dec Hex CharFunction Code Transmit Intercharacter, Interfunction, and Intermessage DelaysIntercharacter Delay User Specified Intercharacter Delay Interfunction Delay Intermessage Delay3800/3900 User’s Guide Data Format Editor Introduction Scan the Enter Data Format symbol Primary/Alternate FormatData Formatting To Add a Data FormatData Format Editor Commands Other Programming SelectionsMove Commands Data Format Editor Data Formatter Alternate Data Formats3800/3900 User’s Guide Secondary RS-232 Connection Secondary InterfaceSecondary Code 39 Wand Emulation Non Decoded Output Laser Emulation Polarity Secondary Non Decoded Output Laser EmulationNon Decoded Output Laser Emulation Transmission Rate Disabling the Secondary Interface Secondary Trigger ModeNon Decoded Laser Emulation Idle 3800/3900 User’s Guide Introduction SymbologiesAll Symbologies Message Length Description Codabar Start/Stop CharactersCheck Character Codabar ConcatenationCodabar Message Length Code Code 39 Message Length Code 39 Append BaseFull Ascii Interleaved 2 Check DigitInterleaved 2 of 5 Message Length Strict DecodingCode 93 Message Length Code 2 of 5 Message Length Code 2Iata Code 2 Matrix 2 Iata Code 2 of 5 Message LengthMatrix 2 of 5 Message Length Check Digits Required Code 11 Message Length GS Substitution Telepen Code 128 Message LengthTelepen Output Telepen Message LengthNumber System Addenda Required UPC aAddenda Addenda Separator UPC Strict DecodingUPC E0 and UPC E1 UPC E ExpandUPC E Addenda Addenda Separator EAN/JAN EAN/JAN Isbn Enable Default All EAN/JAN 8 Settings Addenda Addenda Separator MSI MSI Message Length Plessey Plessey Message LengthRSS-14 RSS LimitedRSS Expanded RSS Expanded Message LengthChina Post Code China Post Message LengthOff Minimum Message Length Maximum Message Length Scan Diagnostics Show GLI Blocks3800/3900 User’s Guide Minimum Message Length Maximum Message Length Eanucc Composite Eanucc Composite SymbologyEnable UPC/EAN Version Eanucc Composite Code Message Length 3800/3900 User’s Guide Procedure Cloning3800/3900 User’s Guide Visual Menu Temporary Visual Menu ConfigurationInstalling Visual Menu from the Web Visual Menu IntroductionUpgrading USB Firmware Function Code HEX/ASCII Value Full Ascii Ctrl + Interface KeysKeyboard Function Relationships Country Codes PS/2 Compatibles IBM XTs IBM, DDC, Memorex Interface Keys Supported Interface KeysIBM AT/XT Compatibles Telex, HarrisMemorex Telex SYN PF1 ETB PF2 Can PF3 PF4 SUB PF5 ESC PF6 PF7 PF8 PF9Esprit 200 Interface Keys Ansi AsciiSupported Interface Keys Apple Mac/iMac Show Software Revision To Add a Test Code I.D. Prefix to All SymbologiesUtilities Show Data FormatSpecular Effect Reduction Conventions Serial Programming CommandsMenu Command Syntax Responses Query CommandsConcatenation of Multiple Commands Examples of Query Commands Trigger Commands Resetting the Factory SettingsMenu Commands Setting Serial Selection CommandWNDPAT0 Output Selections Prefix/Suffix Selections Data Formatter SelectionsSymbologies SelectionsCBRSSX0 I25STR0 Teldft UPAARQ0 UPAARQ1 E13ARQ0 Plsdft Mpddft Parameter Specification Product SpecificationsProduct Specifications Product Specifications Cable Pinouts StandardLaser CompatiblePinouts Standard CableWandEmulation Pinouts Primary Interface Cables Serial Output Standard CableStandard Cable Pinouts USB3800/3900 User’s Guide Cleaning the Scanner’s Window MaintenanceMaintenance Inspecting Cords and ConnectorsTo Replace the Interface Cable TroubleshootingReplacing the Interface Cable Is the scanner having trouble reading your symbols? 3800/3900 User’s Guide Product Service and Repair Customer SupportAsia Pacific Online Product Service and Repair AssistanceTechnical Assistance JapanOnline Technical Assistance Limited Warranty 3800/3900 User’s Guide 3800/3900 User’s Guide Page Page Page Sample Symbols Matrix 2 Programming Chart Save Discard Hand Held Products, Inc