| Power Conditioner |
SPECIFICATIONS |
|
Type | Power Conditioner & Suppressor |
Load Rating | 15A |
FRONT PANEL |
|
Outlets | 2 Unswitched |
Lights | 1 Pull Out LED with Dimmer Switch |
Activation Switch | Rocker |
Circuit Breaker | 15A Resettable |
AC Mains Voltmeter | Three Digits, Digital |
Indicators | AC Power On, Abnormal Voltage, AC Fault, Breaker Open, Wiring Fault |
REAR PANEL |
|
AC Outlets | 8 Outlets total, 6 Filtered, 1 High Power |
LED Light Socket | XLR Socket to provide 12VDC for optional 16" Gooseneck Lamp. |
LED Light Switch | Two position (On / Off) |
AC Mains Power Cord | 9' (3m), |
TECHNICAL DATA |
|
Current Rating | 15 amps |
Operating Voltage | 102VAC – 132VAC |
High Voltage Surge Protection | Trigger at 133VAC, 1ms typically |
Low Voltage Protection | Trigger 101VAC, 1ms typically |
Voltmeter Accuracy | ±1.5VAC |
Spike Protection Modes | DCS (Dual Clamping Suppression) Circuitry on Incoming AC Mains and Each Section Output |
Min. Spike Clamping Voltage | 460VRMS @ 3,000A |
Max. Spike Clamping Voltage | 6000V |
Max. Spike Clamping Resp. Time | 1 nanosecond |
Spike Clamping Voltage @ 100A | 1250Vp for 20µs |
Maximum Surge Current | 6,500A |
Energy Rating @ 2ms | 2000 Joules |
Noise Attenuation EMI/RFI | 10dB @ 10kHz / 40dB @ 100kHz / 100dB @ 10MHz |
Temperature Range | 5° – 35°c |
Humidity Range | 5% to 95% R.H. |
MECHANICAL |
|
Chassis Finish | Black |
Mounting | Rack Mount, 1RU |
Height | 1.75" (1RU, 44.5mm) |
Width | 19" (215.9mm) |
Depth | 8.5" (548.64mm) |
Weight | 7.6 lbs (3.45kg) |
Power Consumption | 12 watts |
Agency Listings | MET (UL 1449 Code) |
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone:
– 10 – | ETAsys.com |