Power Conditioner
8 9 10 11 12
6 |
|
|
| 7 |
|
|
6.AC Mains Function Display
7.AC Mains Voltage Display – This display will illuminate when the AC Mains power cord is plugged into an AC source. Note: the display has a 1.5% tolerance.
8.Power ON LED – Will illuminate green when the AC Mains Power Switch is in the ON Position.
9.AC Mains Wiring Polarity Fault Indicator – The Red LED will illuminate if the AC Mains Power Cord is plugged into an AC Mains outlet that is wired incorrectly, such as when the AC "Hot" and the AC "Neutral" are wired backwards.
10.AC Mains Breaker Indicator – This Red LED will illuminate if the maximum unit current draw is exceeded. The breaker rating is 15A, but will handle higher peaks for a short period of time. The LED will illuminate until the AC Mains Breaker is reset.
11.AC Fault Indicator – Although the Dual Clamping Suppression (DCS) circuit virtually assures protection from most transient voltage spikes and surges. Nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage. In the rare instance that this occurs and the DCS circuit has been damaged, the Red “AC Fault” LED indicator will illuminate and an internal buzzer will sound. The
12.AC Mains Abnormal Voltage Indicator – This LED flashes under several AC Mains fault situations listed below. Normal operating voltages for AC Mains voltage is considered to be between 108VAC and 127VAC. Any voltages exceeding those parameters are considered a risk to damage equipment plugged into the
High AC Line Mains – The Abnormal Voltage LED will flash between 128VAC – 132VAC indicating possible damage may occur to equipment due to high AC Mains voltage. The
Low AC Line Mains – The Abnormal Voltage LED will flash between 101VAC – 107VAC indicating possible damage may occur to equipment due to low AC Mains voltage. The
Extreme High AC Line Mains – If the AC Mains reach 133VAC, the EVS (Extreme Voltage Shutdown) circuit will be triggered to shut off the AC outlets while activating the Abnormal Voltage LED. The Red LED will illuminate steady and the AC Mains Voltage Meter will flash OL (Overload), indicating possible damage may occur to the equipment plugged into the
Extreme Low AC Line Mains – If the AC Mains lowers to 101VAC, the EVS (Extreme Voltage Shutdown) circuit will be triggered to shut off the AC outlets while activating the Abnormal Voltage LED. The Red LED will illuminate steady and the AC Mains Voltage Meter will flash OL (Overload), indicating possible damage may occur to the equipment plugged into the
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone:
– 7 – | ETAsys.com |