Dell R820 owner manual SD vFlash Card, Installing Expansion-Card Risers, Riser guide-front top

Page 69

7.riser guide-front (top)

Figure 35. Connectors on the Expansion Card Riser 3

1.chassis intrusion switch

2.expansion-card connector (slot 6)

3.expansion-card connector (slot 7)

4.If applicable, remove or install an expansion card on the riser.

5.Replace the expansion-card riser.

6.Close the system.

7.Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Installing Expansion-Card Risers

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1.If applicable, reinstall the expansion card(s) into the expansion card riser.

2.Align the expansion-card riser with the connector and the riser guides on the system board.

3.Lower the expansion-card riser until the expansion-card riser is firmly seated.

4.Close the system.

5.Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

6.Install any device drivers required for the card as described in the documentation for the card.

SD vFlash Card

A vFlash SD card is a Secure Digital (SD) card that plugs into the vFlash SD card slot in the system. It provides persistent on-demand local storage and a custom deployment environment that allows automation of server configuration, scripts, and imaging. It emulates USB device(s). For more information, see the iDRAC7 User's Guide at dell.com/support/ manuals.

69

Image 69
Contents Regulatory Model E21S Series Regulatory Type E21S001 Dell Inc. All Rights Reserved Contents Installing System Components General Memory Module Installation GuidelinesInstalling Memory Modules Installing The Power Supply Blank Installing The Integrated Storage Controller CardInstalling The Hard-Drive Backplane Internal USB Memory Key OptionalTroubleshooting Your System Using System DiagnosticsJumpers And Connectors Technical Specifications System MessagesGetting Help Page Indicator, Button, or Icon Description Connector Front-Panel Features And IndicatorsLCD Panel Features Setup Menu Home ScreenView Menu Hard-Drive Indicator Patterns Steady green Drive online Blinks green three Back-Panel Features And IndicatorsSeconds PCIe expansion card slotsPower supply PSU2 Or 1100 W When available NIC Indicator CodesLink indicator Activity indicator System identification buttonGreen Link indicator is Power Indicator CodesAC power supply status indicator/handle DC power supply status indicatorOther Information You May Need Keystroke Description Choosing The System Boot ModeF10 F11 F12Entering System Setup Responding To Error MessagesUsing The System Setup Navigation Keys System Setup Main Screen System Setup OptionsSystem Bios Screen System Information ScreenProcessor Settings Screen Memory Settings ScreenPrefetcher option is set to Enabled Option is set to EnabledExecute Disable Execute Disable option is set to EnabledSata Settings Screen Boot Settings ScreenIntegrated Devices Screen Serial Communications Screen System Profile Settings Screen System Security Screen Miscellaneous Settings System And Setup Password FeaturesAssigning a System And/Or Setup Password Operating With a Setup Password Enabled Using Your System Password To Secure Your SystemUsing The Boot Manager Navigation Keys Entering The Uefi Boot ManagerBoot Manager Screen Exits the Boot Manager and proceeds with system bootIDRAC Settings Utility Entering The iDRAC Settings UtilityEmbedded System Management IDRAC Settings screen is displayed Changing The Thermal SettingsPage Recommended Tools Front Bezel OptionalRemoving The Front Bezel Opening And Closing The System Installing The Front BezelOpening The System Release latch Keylock Front bezel Locking hookInside The System Closing The SystemSystem cover Latch Latch release lock Heat sink for processor QPI connectors Cooling-fan assemblyCable securing bracket DIMMsProcessor Expansion Module Removing the Processor Expansion ModuleHeat sink for processor DIMMs Processor expansion module Removing and Installing the Processor Expansion Module Installing The Processor Expansion Module Filler bracket Standoffs TabsNotches Cooling Shroud Removing The Cooling ShroudCooling shroud Touch points System Memory Installing The Cooling ShroudMemory Socket Locations on the System Board Processor Memory channels are organized as followsGeneral Memory Module Installation Guidelines Mode-Specific Guidelines1066 Advanced ECC Lockstep Sample Memory Configurations1R x8, 1600 MT/s 1R x8, 1333 MT/s 1R x8, 1333 MT/s 1R x8, 1600 MT/s A1, A2, B1, B22R x8, 1333 MT/s 2R x8, 1600 MT/s 2R x8, 1333 MT/s2R x4, 1600 MT/s B3, B4, B5, B6 256 2R x4, 1333 MT/s 192 2R x4, 1333 MT/s2R x4, 1600 MT/s 384 2R x4, 1333 MT/s256 2R x4, 1333 MT/s Removing Memory Modules768 4R x4, 1333 MT/s 1024 4R x4, 1066 MT/sPage Hard Drives Installing Memory ModulesRemoving a 2.5 Inch Hard-Drive Blank Installing a 2.5 Inch Hard-Drive BlankRemoving a Hot-Swap Hard Drive Hard-drive blank Release buttonRelease button Hard drive Hard-drive carrier handle Installing a Hot-Swap Hard DriveHard-drive carrier Hard drive Screws Removing a Hard Drive From a Hard-Drive CarrierInstalling a Hard Drive Into a Hard-Drive Carrier Optical Drive OptionalRemoving The Optical Drive Optical drive Power and data cable Release tab Installing The Optical DriveCooling Fans Your system supports hot-swappable cooling fansRemoving a Cooling Fan Removing and Installing a Cooling FanRemoving The Cooling-Fan Assembly Installing The Cooling FanCooling-fan assembly Guide pins Cooling fans Installing The Cooling-Fan AssemblyInternal USB Memory Key Optional Replacing The Internal USB KeyUSB memory key connector Expansion Cards Installation GuidelinesExpansion Cards And Expansion-Card Risers Riser PCIe SlotFull Height Pcie Extender Adapter SSD Removing An Expansion Card From An Expansion-Card Riser 1 OrExpansion-card holder Expansion-card riser Expansion card Expansion-card connectorPage Removing An Expansion Card From The Expansion-Card Riser Page Grooves Expansion-card holder Tab Expansion card Installing An Expansion Card Into The Expansion-Card RiserRemoving Expansion-Card Risers Removing and Installing the Expansion Card RiserTouch points Connector Expansion-card riser Expansion-card connector slotRiser guide-back right Riser guide-back left Connector Riser guide-front Installing Expansion-Card Risers SD vFlash CardRiser guide-front top Internal Dual SD Module Replacing An SD vFlash CardRemoving The Internal Dual SD Module Installing the Internal Dual SD Module Blue pull tabSD card Retention tab Dual SD module Internal SD Card Installing An Internal SD CardIntegrated Storage Controller Card Removing An Internal SD CardRemoving The Integrated Storage Controller Card Removing the SAS Cable ConnectorStorage-controller card SAS connectors Storage-controller card Cables Expansion-card latchRiser card Installing The Integrated Storage Controller Card Network Daughter CardCable securing bracket Cable securing guide SAS cables Screws PCH shroud Removing The Network Daughter CardUse the following procedure when Installing The Network Daughter CardProcessors Captive screws Touch pointRemoving The Processor Removing and Installing the Processor Heat Sink Processor Shield Opening and Closing Lever Sequence Close-lock symbolProcessor shield Installing The ProcessorHot Spare Feature Power SuppliesConnector Power supply Release latch Power supply handle Removing An AC Power SupplyInstalling An AC Power Supply Wiring Instructions For a DC Power SupplySupply voltage -48-60 V DC Current consumption 32 a maximum Grounding post #6-32 nut Locking washer Safety ground wireDC power connector DC power socket Wire -48 Rubber cap Wire RTN Captive screwsInstalling a DC Power Supply Removing a DC Power SupplyConnector Release latch Power supply Power supply status indicatorRemoving The Power Supply Blank Installing The Power Supply BlankPower supply blank Replacing The System Battery System BatteryRemoving The Hard-Drive Backplane Hard-Drive BackplaneHooks Release tab Securing slots SAS a connector Power connectorSAS B connector Signal connector Signal connector SAS B connectorCabling Diagram-Dual 2.5 Inch x8 Hard-Drive Backplane Hard-drive backplane SAS a connectorPCIe SSD backplane Connector Diagram-2.5 Inch x4 PCIe SSD BackplanePCIe SSD a connector Signal connector PCIe SSD D connectorPerc card SAS B connector System board Signal connector Hooks Securing slots Connectors Release tabsCable retention bracket Power connector Installing The Hard-Drive BackplaneControl Panel Assembly Removing The Control-Panel AssemblyControl-panel connector cable Captive screws System Board Installing The Control-Panel AssemblyRemoving The System Board Information tag TabsPage System board System-board holder Thumb screw Installing The System BoardPage Troubleshooting External Connections Troubleshooting The Video SubsystemTroubleshooting a USB Device Troubleshooting a NIC Troubleshooting a Serial I/O DeviceTroubleshooting a Damaged System Troubleshooting a Wet SystemTroubleshooting Power Supplies Troubleshooting The System BatteryTroubleshooting Cooling Problems 106Troubleshooting System Memory Troubleshooting Cooling FansTroubleshooting An SD Card Troubleshooting An Internal USB KeyTroubleshooting a Tape Backup Unit Troubleshooting An Optical DriveTroubleshooting a Storage Controller Troubleshooting a Hard DriveTroubleshooting Expansion Cards Troubleshooting Processors Dell Online Diagnostics Dell Embedded System Diagnostics When To Use The Embedded System DiagnosticsRunning The Embedded System Diagnostics System Diagnostic Controls Least one event description is recorded114 Jumper Setting Description System Board Jumper SettingsConnector Description System Board ConnectorsBattery connector Riser 1 connectorOptical drive Sata connector Front Panel USB connectorDisabling a Forgotten Password Expansion slots using riser card Expansion BusMemory Drives Connectors BackFront InternalExpanded Operating Temperature Environmental TemperatureVideo Relative Humidity EnvironmentalMaximum Vibration Maximum ShockGaseous Contamination 124 LCD Messages System Error MessagesViewing LCD Messages Removing LCD MessagesAMP0302 Message Error CodeDetails ActionBAT0002 Message ASR0003 MessageBAT0017 Message CPU0000 MessageCPU0023 Message CPU0010 MessageCPU0204 Message CPU0700 MessageCPU0702 Message CPU0703 MessageCPU0704 Message Action Reinstall or reconnect the hardware HWC2003 Message If the issue persists, see Getting HelpFAN0000 Message Details Fan operating speed is out of range ActionMEM0001 Message MEM0000 MessageMEM0007 Message MEM0701 MessageMEM8000 Message MEM1208 MessagePCI1302 Message PCI1304 MessagePCI1342 Message PCI1320 MessagePCI1348 Message PCI1360 MessagePST0129 Message PST0128 MessagePSU0001 Message PSU0002 MessagePSU0016 Message PSU0006 MessagePSU0031 Message PSU0032 MessagePSU0035 Message PSU0034 MessagePSU0036 Message PSU0037 MessageSystem power inventory change PSU1201 Message Power supply redundancy is lost DetailsConfiguration and power consumption System power consumptionRFM1201 Message RFM1014 MessageRFM2001 Message RFM2002 MessageAppear if the user disabled event logging SEL0006 Message All event logging is disabled DetailsPower. If problem persists call support Security may be compromisedFailed Issues persists, contact supportFailures TMP0121 MessageReview system logs for power supply exceptions Diagnostic MessagesReinstall system cables Alert Messages142 Contacting Dell Getting Help
Related manuals
Manual 8 pages 22.5 Kb Manual 149 pages 54.63 Kb