Dell M1000E owner manual Avocent Analog iKVM Switch Module Features

Page 19

Module Indicator

Description

USB connectors

Allows a keyboard and mouse to be connected to the system.

Video connector

Allows a monitor to be connected to the system.

ACI port

Allows connection of one or more servers to a Dell console switch with an Analog

 

Rack Interface (ARI) port, such as an external digital or analog switch.

Link indicator

The ACI is not connected to the external switch.

Off

Green

The ACI is connected to the external switch.

Activity indicator

Data is not being sent or received.

Off

Amber blinking

Data is being sent or received.

Avocent Analog iKVM Switch Module Features

Local iKVM access can be remotely disabled on a per blade basis, using the blade’s iDRAC interface (access is enabled by default).

NOTE: A console session (enabled by default) to a given blade is available for both iDRAC interface and iKVM users. Users connected to a blade's console using iDRAC and the iKVM see the same video and are able to type commands. If not required, sharing can be disabled using the iDRAC console interface.

One VGA connector. The iKVM supports a video display resolution range from 640 x 480 at 60 Hz up to 1280 x 1024 x 65,000 colors (non-interlaced) at 75 Hz.

Two USB ports for keyboard and mouse.

NOTE: The iKVM USB ports do not support storage devices.

RJ-45 Analog Console Interface (ACI) port for tiering with Dell and Avocent analog KVM and KVM over IP switches with Analog Rack Interface (ARI) ports.

NOTE: Although the ACI port is an RJ-45 connector and uses Cat5 (or better) cabling, it is not an Ethernet network interface port. It is only used for connection to external KVM switches with ARI ports, and does not support native KVM over IP.

The iKVM can also be accessed from the front of the enclosure, providing front or rear panel KVM functionality, but not at the same time. For enhanced security, front panel access can be disabled using the CMC’s interface.

NOTE: Connecting a keyboard, video, and mouse to the enclosure front panel disables video output to the iKVM back panel port. It does not interrupt iDRAC video and console redirection.

You can use the iKVM to access the CMC console directly, using RACADM or using the web-based interface. For more information, see Using the iKVM Module in the CMC User’s Guide at support.dell.com/manuals.

19

Image 19
Contents Dell PowerEdge M1000e Enclosure Page Contents Configuring The I/O Modules Installing Enclosure Components Technical Specifications 101 Troubleshooting The EnclosureGetting help 107 System Overview About your systemBlade Numbering Full Height Blades Control-Panel Features System Control-Panel FeaturesLCD Module LCD Display LCD Module FeaturesUsing The LCD Module Menus Configuration WizardPage Back-Panel Features Back-Panel FeaturesBack-Panel Module Bay Numbering Power Supply IndicatorsPower Supply Indicators Fan Module Indicators Fan Module IndicatorsAvocent Analog iKVM Switch Module Indicators Avocent iKVM Analog Switch Module OptionalAvocent Analog iKVM Switch Module Features CMC Module CMC Module FeaturesCMC CMC Fail-Safe ModeDaisy-Chain CMC Network Connection CMC Daisy-Chaining System MessagesDocumentation Matrix Quick Resource Locator Quick Resource LocatorBefore You Begin Initial Setup SequenceConfiguring The CMC Using The LCD Configuration Wizard Initial CMC Network ConfigurationConfiguring The CMC Using a Management Station And CLI Logging In To The CMC Using The Web-Based InterfaceAdding And Managing CMC Users Setting The First Boot Device For Servers Configuring iDRAC Networking Using The Web-Based InterfaceInstalling Or Updating The CMC Firmware Configuring And Managing PowerDownloading The CMC Firmware Updating The iKVM Firmware Configuring The Optional iKVM Switch ModuleUpdating The CMC Firmware Using The Web-Based Interface Updating The CMC Firmware Using RacadmTiering The Avocent iKVM Switch From An Analog KVM Switch Tiering The Avocent iKVM Switch From a Digital KVM SwitchConfiguring The Analog Switch Viewing And Selecting Servers FlexAddressStartingmac00188BFFDCFA + 0xCF = endingmac00188BFFDDC9 FlexAddress PlusFabric a General I/O Module Configuration GuidelinesNetwork Information ConnectivityFabric C Fabric BHalf-Height Blades PowerEdge M610x OnlyMezzanine Cards Full-Height BladesModule or Pass-through Standard LOM Dual-Port Mapping Module Port Mapping-Full-Height BladesDual-Port Mezzanine Cards Blade Module Mezz1FabC Port Mezz2FabB Mezz3FabC Mezz4FabB Blade Module Mezz3FabC Port Mezz4FabB Mezz1FabC Mezz2FabB Page Variable value From 1 to Quad-Port Mezzanine CardsModule Port MappingHalf-Height Blades Example of I/O Module Port Assignments Half-Height Blade Example of Half-Height Blade Port Mapping Modules-Switches Cisco Nexus B22 Fabric Extender Module Brocade M6505 16 Gbps FC SAN I/O ModuleCisco Nexus B22 Fabric Extender Module Dell PowerEdge M I/O Aggregator SwitchDell PowerEdge M I/O Aggregator Switch Dell Force10 MXL 10/40 GbE SwitchExpansion slots Dell PowerConnect KR 8024-k Switch Mellanox M4001F/M4001Q/M4001T Infiniband Switch I/O ModuleDell PowerConnect KR 8024-k Switch Dell PowerConnect M8428-k 10 Gb Converged Network SwitchMellanox M2401G DDR Infiniband Switch I/O Module Mellanox M2401G DDR Infiniband Switch Module Mellanox M3601Q QDR Infiniband Switch I/O ModuleMellanox M3601Q QDR Infiniband Switch I/O Module Cisco Catalyst Ethernet Switch I/O ModulesCisco Catalyst Ethernet Switch Module Features Dell PowerConnect M6348 1 Gb Ethernet Switch I/O ModulePowerConnect M6348 1 Gb Ethernet Switch I/O Module Features Dell PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M6220 Ethernet Switch I/O Module Dell PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module Brocade M5424 FC8 I/O ModuleBrocade M5424 FC8 I/O Module Dell 4 Gbps Fibre Channel Pass-Through Module Modules-Pass-ThroughPost Dell 10 GbE KR Pass-Through I/O Module Dell 10 GbE KR Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through ModuleGb Ethernet Pass-Through Module 10/100/1000 Mb Ethernet Pass-Through I/O ModuleActivity indicators Recommended Tools Removing And Installing a BladeRemoving a Blade Install the I/O connector cover over the I/O connector Installing a Blade Power Supply ModulesAC Power Supply Modules Power Supply BlanksPower Cable Retention Clip Installing An AC Power Supply Wiring Instructions For a DC Power Supply DC Power Supply ModulesInput Requirements Assembling The DC Input Power Wires And DC Power Connector Assembling the DC Input Power Wires Removing a DC Power Supply Installing a DC Power Supply Removing a Fan Module Fan ModulesRemoving a CMC Module Installing a Fan ModuleCMC Module SD Card Installing a CMC ModuleRemoving An iKVM Module IKVM ModuleModules Installing An iKVM ModuleRemoving An I/O Module Installing An I/O ModuleRemoving The Enclosure Bezel Enclosure BezelRemoving The Front Module Cage Assembly And Midplane Installing The Enclosure BezelEnclosure Midplane Front module cage assembly Enclosure Torx T20 screws Removing and Installing the Midplane Installing The Midplane And Front Module Cage AssemblyRemoving The Control Panel Enclosure Control Panel AssemblyRemoving The LCD Module Installing The Control PanelRemoving and Installing the LCD Module Installing The LCD ModuleTroubleshooting Enclosure Components Troubleshooting The EnclosureTroubleshooting Power Supply Modules Troubleshooting a Wet EnclosureTroubleshooting The iKVM Module Troubleshooting Fan ModulesTroubleshooting I/O Modules Enclosure Specifications Technical SpecificationsUSB Module Specifications Page For temperatures between 40 C and 45 C, de Page Quick Resource Locator Contacting DellDocumentation Feedback
Related manuals
Manual 2 pages 36.05 Kb Manual 103 pages 3.58 Kb Manual 86 pages 34.71 Kb Manual 86 pages 40.45 Kb Manual 12 pages 5.14 Kb

M1000E specifications

The Dell M1000E blade enclosure is a robust and versatile platform designed to optimize data center efficiency and streamline server management. A fundamental component of Dell's PowerEdge series, the M1000E is engineered to house multiple server blades in a compact, modular chassis, enabling organizations to conserve space and reduce power consumption while enhancing performance.

One of the main features of the Dell M1000E is its ability to accommodate up to 16 half-height server blades or 8 full-height server blades. This flexibility allows for a diverse range of configurations tailored to specific workloads, whether for virtualization, database management, or application hosting. The chassis provides shared power supplies and cooling, further contributing to the enclosure's efficient operation.

In terms of connectivity, the M1000E includes integrated high-speed networking capabilities. It can support multiple generations of networking technologies, ranging from Gigabit Ethernet to 10 Gigabit Ethernet, and offers options for Fibre Channel and InfiniBand connections. This extensive range of networking options ensures that organizations can integrate the M1000E into existing infrastructures seamlessly.

The Dell M1000E also utilizes advanced management tools to simplify administration and monitoring. One of the standout features is the Dell OpenManage suite, which provides a comprehensive set of tools for hardware management and system updates. Users gain insights into system health, performance, and power usage, enabling proactive maintenance and optimization of resources.

The enclosure is designed with scalability in mind. As businesses grow, the M1000E can be expanded easily by adding more blades without the need for significant reconfiguration. This scalability ensures that IT departments can respond rapidly to changing demands, ensuring that resources align with organizational requirements.

From a security standpoint, the M1000E provides multiple layers of protection, including secure access controls and configurable management interfaces. This helps safeguard sensitive information and ensures compliance with stringent data protection regulations.

Overall, the Dell M1000E blade enclosure represents a compelling solution for modern data centers, merging performance, efficiency, and scalability into a single chassis designed to meet the demands of today’s enterprise environments. Its advanced technologies and features make it a valuable asset for organizations looking to enhance their IT infrastructure.