Dell M1000E owner manual CMC Fail-Safe Mode, Cmc

Page 21

Monitors and automatically controls cooling fans based on actual ambient and internal temperature measurements.

Provides comprehensive enclosure inventory and status/error reporting.

CMC fail-safe mode. For more information, see CMC Fail-Safe Mode.

The CMC provides a mechanism for centralized configuration of the following:

The enclosure’s network and security settings

Power redundancy and power ceiling settings

I/O switches and iDRAC network settings

First boot device on the server blades

Checks I/O fabric consistency between the I/O modules and blades and disables components if necessary to protect the system hardware

User access security

NOTE: It is recommended that you isolate chassis management from the data network. Dell cannot support or guarantee uptime of a chassis that is improperly integrated into your environment. Due to the potential of traffic on the data network, the management interfaces on the internal management network can be saturated by traffic intended for servers. This results in CMC and iDRAC communication delays. These delays may cause unpredictable chassis behavior, such as CMC displaying iDRAC as offline even when it is up and running, which in turn causes other unwanted behavior. If physically isolating the management network is impractical, the other option is to separate CMC and iDRAC traffic to a separate VLAN. The CMC and individual iDRAC network interfaces can be configured to use a VLAN with the racadm setniccfg command. For more information, see the Dell Chassis Management Controller Administrator Reference Guide at support.dell.com/manuals.

CMC Fail-Safe Mode

Similar to the failover protection offered by the redundant CMC, the M1000e enclosure enables the fail- safe mode to protect the blades and I/O modules from failures. The fail-safe mode is enabled when no CMC is in control of the chassis. During the CMC failover period or during a single CMC management loss:

you cannot turn on newly installed blades

existing blades cannot be accessed remotely

chassis cooling fans run at 100% for thermal protection of the components

blade performance reduces to limit power consumption until management of the CMC is restored

The following are some of the conditions that can result in CMC management loss:

Condition

Description

CMC removal

Chassis management resumes after replacing CMC, or after failover to standby

 

CMC.

CMC network

Chassis management resumes after the chassis fails over to the standby CMC.

cable removal or Network failover is only enabled in redundant CMC mode.

network

 

connection loss

 

CMC reset

Chassis management resumes after the CMC reboots or chassis fails over to the

 

standby CMC.

21

Image 21
Contents Dell PowerEdge M1000e Enclosure Page Contents Configuring The I/O Modules Installing Enclosure Components Troubleshooting The Enclosure Technical Specifications 101Getting help 107 System Overview About your systemBlade Numbering Full Height Blades Control-Panel Features System Control-Panel FeaturesLCD Module LCD Display LCD Module FeaturesUsing The LCD Module Menus Configuration WizardPage Back-Panel Features Back-Panel FeaturesBack-Panel Module Bay Numbering Power Supply IndicatorsPower Supply Indicators Fan Module Indicators Fan Module IndicatorsAvocent Analog iKVM Switch Module Indicators Avocent iKVM Analog Switch Module OptionalAvocent Analog iKVM Switch Module Features CMC Module CMC Module FeaturesCMC CMC Fail-Safe ModeDaisy-Chain CMC Network Connection CMC Daisy-Chaining System MessagesDocumentation Matrix Quick Resource Locator Quick Resource LocatorBefore You Begin Initial Setup SequenceConfiguring The CMC Using The LCD Configuration Wizard Initial CMC Network ConfigurationConfiguring The CMC Using a Management Station And CLI Logging In To The CMC Using The Web-Based InterfaceAdding And Managing CMC Users Setting The First Boot Device For Servers Configuring iDRAC Networking Using The Web-Based InterfaceConfiguring And Managing Power Installing Or Updating The CMC FirmwareDownloading The CMC Firmware Updating The CMC Firmware Using The Web-Based Interface Configuring The Optional iKVM Switch ModuleUpdating The CMC Firmware Using Racadm Updating The iKVM FirmwareTiering The Avocent iKVM Switch From An Analog KVM Switch Tiering The Avocent iKVM Switch From a Digital KVM SwitchConfiguring The Analog Switch Viewing And Selecting Servers FlexAddressStartingmac00188BFFDCFA + 0xCF = endingmac00188BFFDDC9 FlexAddress PlusNetwork Information General I/O Module Configuration GuidelinesConnectivity Fabric aFabric C Fabric BMezzanine Cards PowerEdge M610x OnlyFull-Height Blades Half-Height BladesModule or Pass-through Standard LOM Dual-Port Mapping Module Port Mapping-Full-Height BladesDual-Port Mezzanine Cards Blade Module Mezz1FabC Port Mezz2FabB Mezz3FabC Mezz4FabB Blade Module Mezz3FabC Port Mezz4FabB Mezz1FabC Mezz2FabB Page Variable value From 1 to Quad-Port Mezzanine CardsModule Port MappingHalf-Height Blades Example of I/O Module Port Assignments Half-Height Blade Example of Half-Height Blade Port Mapping Modules-Switches Cisco Nexus B22 Fabric Extender Module Brocade M6505 16 Gbps FC SAN I/O ModuleCisco Nexus B22 Fabric Extender Module Dell PowerEdge M I/O Aggregator SwitchDell PowerEdge M I/O Aggregator Switch Dell Force10 MXL 10/40 GbE SwitchExpansion slots Dell PowerConnect KR 8024-k Switch Mellanox M4001F/M4001Q/M4001T Infiniband Switch I/O ModuleDell PowerConnect KR 8024-k Switch Dell PowerConnect M8428-k 10 Gb Converged Network SwitchMellanox M2401G DDR Infiniband Switch I/O Module Mellanox M2401G DDR Infiniband Switch Module Mellanox M3601Q QDR Infiniband Switch I/O ModuleMellanox M3601Q QDR Infiniband Switch I/O Module Cisco Catalyst Ethernet Switch I/O ModulesCisco Catalyst Ethernet Switch Module Features Dell PowerConnect M6348 1 Gb Ethernet Switch I/O ModulePowerConnect M6348 1 Gb Ethernet Switch I/O Module Features Dell PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M6220 Ethernet Switch I/O Module Dell PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module Brocade M5424 FC8 I/O ModuleBrocade M5424 FC8 I/O Module Dell 4 Gbps Fibre Channel Pass-Through Module Modules-Pass-ThroughPost Dell 10 GbE KR Pass-Through I/O Module Dell 10 GbE KR Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through ModuleGb Ethernet Pass-Through Module 10/100/1000 Mb Ethernet Pass-Through I/O ModuleActivity indicators Removing And Installing a Blade Recommended ToolsRemoving a Blade Install the I/O connector cover over the I/O connector Installing a Blade Power Supply ModulesAC Power Supply Modules Power Supply BlanksPower Cable Retention Clip Installing An AC Power Supply Wiring Instructions For a DC Power Supply DC Power Supply ModulesInput Requirements Assembling The DC Input Power Wires And DC Power Connector Assembling the DC Input Power Wires Removing a DC Power Supply Installing a DC Power Supply Removing a Fan Module Fan ModulesRemoving a CMC Module Installing a Fan ModuleCMC Module SD Card Installing a CMC ModuleRemoving An iKVM Module IKVM ModuleModules Installing An iKVM ModuleRemoving An I/O Module Installing An I/O ModuleRemoving The Enclosure Bezel Enclosure BezelInstalling The Enclosure Bezel Removing The Front Module Cage Assembly And MidplaneEnclosure Midplane Front module cage assembly Enclosure Torx T20 screws Removing and Installing the Midplane Installing The Midplane And Front Module Cage AssemblyRemoving The Control Panel Enclosure Control Panel AssemblyRemoving The LCD Module Installing The Control PanelRemoving and Installing the LCD Module Installing The LCD ModuleTroubleshooting Enclosure Components Troubleshooting The EnclosureTroubleshooting Power Supply Modules Troubleshooting a Wet EnclosureTroubleshooting The iKVM Module Troubleshooting Fan ModulesTroubleshooting I/O Modules Enclosure Specifications Technical SpecificationsUSB Module Specifications Page For temperatures between 40 C and 45 C, de Page Quick Resource Locator Contacting DellDocumentation Feedback
Related manuals
Manual 2 pages 36.05 Kb Manual 103 pages 3.58 Kb Manual 86 pages 34.71 Kb Manual 86 pages 40.45 Kb Manual 12 pages 5.14 Kb

M1000E specifications

The Dell M1000E blade enclosure is a robust and versatile platform designed to optimize data center efficiency and streamline server management. A fundamental component of Dell's PowerEdge series, the M1000E is engineered to house multiple server blades in a compact, modular chassis, enabling organizations to conserve space and reduce power consumption while enhancing performance.

One of the main features of the Dell M1000E is its ability to accommodate up to 16 half-height server blades or 8 full-height server blades. This flexibility allows for a diverse range of configurations tailored to specific workloads, whether for virtualization, database management, or application hosting. The chassis provides shared power supplies and cooling, further contributing to the enclosure's efficient operation.

In terms of connectivity, the M1000E includes integrated high-speed networking capabilities. It can support multiple generations of networking technologies, ranging from Gigabit Ethernet to 10 Gigabit Ethernet, and offers options for Fibre Channel and InfiniBand connections. This extensive range of networking options ensures that organizations can integrate the M1000E into existing infrastructures seamlessly.

The Dell M1000E also utilizes advanced management tools to simplify administration and monitoring. One of the standout features is the Dell OpenManage suite, which provides a comprehensive set of tools for hardware management and system updates. Users gain insights into system health, performance, and power usage, enabling proactive maintenance and optimization of resources.

The enclosure is designed with scalability in mind. As businesses grow, the M1000E can be expanded easily by adding more blades without the need for significant reconfiguration. This scalability ensures that IT departments can respond rapidly to changing demands, ensuring that resources align with organizational requirements.

From a security standpoint, the M1000E provides multiple layers of protection, including secure access controls and configurable management interfaces. This helps safeguard sensitive information and ensures compliance with stringent data protection regulations.

Overall, the Dell M1000E blade enclosure represents a compelling solution for modern data centers, merging performance, efficiency, and scalability into a single chassis designed to meet the demands of today’s enterprise environments. Its advanced technologies and features make it a valuable asset for organizations looking to enhance their IT infrastructure.