Cobra Electronics CPI 800 owner manual Troubleshooting Guide, Specifications, Solution

Page 10

Troubleshooting Guide

Operation

Troubleshooting Guide

Problem/Symptom

Possible Causes

Solution

Low output voltage

Overload

Reduce the load.

 

No output voltage

Low input voltage

Recharge battery.

 

 

Check connections

 

 

and cable.

 

No output voltage

Thermal

Allow inverter

after prolonged use

shutdown

to cool off.

 

 

Reduce load,

 

 

continuous

 

 

operation input

 

 

current required.

 

 

Improve ventilation;

 

 

Make sure ventilation

 

 

openings in the

 

 

inverter are not

 

 

obstructed.

 

 

Reduce ambient

 

 

temperature.

 

No output voltage,

High input

Make sure

“Protect” indicator

voltage

the inverter is

lighted

 

connected to

 

 

12V battery.

 

 

Check regulation

 

 

of charging system.

 

No output voltage

Short circuit

Check load for

 

 

proper operation.

 

 

 

No output voltage

Inverter

Turn inverter On.

 

 

switched Off

 

 

 

No power

Check wiring

 

to inverter

to inverter.

 

Reverse

Observe

 

DC polarity

correct polarity.

 

Low battery alarm

Poor DC wiring

Check

on all the time

 

connections.

 

Poor battery

Make sure battery

14 English

condition

is fully charged.

 

 

 

Specifications

Operation

Specifications

Continuous output power (1 hour) . . . . . . . . . . . . 800w Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . 1600w Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88% Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83% No load current draw . . . . . . . . . . . . . . . < 0.5A (12.6V) Output waveform (resistive load) . . . Modified sine wave Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V Operating temperature range . . . . . . . . . . . . 0°C – 40°C

(32°F – 104°F) Storage temperature range . . . . . . . . . . . . -40°C – 85°C (-40°F – 185°F)

Protection . . . . . . . . . .Overload, short-circuit, overtemp, reverse polarity, under/over voltage

Notes

All protection is automatically recovered.

To protect the battery, if the unit needs to be restarted after low voltage protection, the voltage of DC input should be above 12V.

To extend the life of the fan, it will stop when there is no load. The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for added safety.

Nothing comes close to a Cobra15

Image 10
Contents Our Thanks To You How Your Cobra Power Inverter WorksHours a day, 7 days a week 773-889-3087 phone Controls /Indicators and Product Features Table of ContentsImportant Safety Information Important Safety InformationGeneral Precautions Cobra 800W Output Waveform Quick Evaluation Before InstallationQuick Evaluation Before Installation Be Sure to Have on HandInstallation Requirements To Connect the Cables Between the Inverter and the Battery Connecting CablesConnecting Cables MountingConnect cable to the power source Generator or the utility lineTo Determine the Battery Ampere-Hour Capacity You Require Power ConsumptionPower Consumption On/Off Switch to OffRed Light and/or Alarm Power & Protection Indicators Operating LimitsOperating Limits Power Output Green LightTroubleshooting Guide Troubleshooting GuideSpecifications SolutionLimited 1-Year Warranty For Products Purchased in the U.S.A WarrantyMaintenance Product Service MaintenanceAccessories and Order Form Item # Cost Each Qty Amount