Cobra Electronics CPI 800 Connect cable to the power source, Generator or the utility line

Page 7

Connecting Cables

Installation

3.Connect cable to the power source:

a.Connect the cable from the Negative (Black) Terminal of inverter to the Negative Terminal of the power source. Make a secure connection.

b.Connect the cable from the Positive (Red) Terminal of the inverter to the Positive Terminal of the power source (the battery’s main fuse or the battery selector switch, if you are using one). Make a secure connection.

You might observe a spark when you make this connection since current can flow to charge capacitors in the inverter.

All power connections to your Cobra® inverter must be Positive to Positive and Negative to Negative.

Connect Power Source

CAUTION Do not connect the inverter and another AC source (such as a generator or utility power) to the AC wiring at the same time. The inverter will be damaged if its output is connected to AC voltage from another source. Damage can even occur if the inverter is switched Off.

CAUTION Do not connect the inverter to an AC branch circuit that has high-power consumption loads. It will not operate electric heaters, air conditioners, stoves, and other electrical appliances that consume more than 800 watts.

CAUTION Loose connectors result in excessive voltage drop and may cause over heated wires and melted insulation.

8 English

Connecting Cables

Installation

CAUTION Reverse polarity connections (positive to negative) will blow internal fuses in the inverter and may permanently damage the unit. Such damage is not covered by the warranty.

CAUTION Remove any jewelry (watch, ring, etc.). Be careful not to short circuit the battery with any metallic object (wrench, etc.).

WARNING 115 volt AC power is potentially lethal. Do not work on AC wiring when it is connected to the inverter (even if it is switched off) unless the DC power source is physically disconnected from the inverter. Also, do not work on AC wiring if it is connected to another AC power source such as

a generator or the utility line.

WARNING You may observe a spark when making the connection because current can flow to charge the capacitors in the inverter. Do not make this connection in the presence of flammable fumes. Explosion or fire may result. Thoroughly ventilate the battery compartment before making this connection.

Nothing comes close to a Cobra9

Image 7
Contents Our Thanks To You How Your Cobra Power Inverter WorksHours a day, 7 days a week 773-889-3087 phone Table of Contents Controls /Indicators and Product FeaturesImportant Safety Information Important Safety InformationGeneral Precautions Be Sure to Have on Hand Quick Evaluation Before InstallationQuick Evaluation Before Installation Cobra 800W Output WaveformInstallation Requirements Mounting Connecting CablesConnecting Cables To Connect the Cables Between the Inverter and the BatteryGenerator or the utility line Connect cable to the power sourceOn/Off Switch to Off Power ConsumptionPower Consumption To Determine the Battery Ampere-Hour Capacity You RequireGreen Light Power & Protection Indicators Operating LimitsOperating Limits Power Output Red Light and/or AlarmSolution Troubleshooting GuideSpecifications Troubleshooting GuideMaintenance WarrantyMaintenance Product Service Limited 1-Year Warranty For Products Purchased in the U.S.AItem # Cost Each Qty Amount Accessories and Order Form