Termination Module

The SANnet II 200 SCSI array terminator board is a field-serviceable FRU that supplies the SCSI termination throughout a base enclosure. It is hot-serviceable but not hot-swappable, so replacing one will require planned downtime. The termination module is essentially hidden between controllers, so it requires the removal of controllers before it can be replaced.

To remove a termination module, first remove all controllers and then remove the termination module by pulling it out from the enclosure. In configurations with single controllers, you must remove the blank controller panel as well as the controller. To install a termination module, slide it into the enclosure until it stops. Reinstall the controllers when done. There is no termination module within expansion enclosures.

FIGURE 10: Termination Module

13

Image 13
Contents SANnet II 200 Scsi Array Technical Product Description Guide Copyright Contents Introduction Key FeaturesManagement Interfaces Architecture FundamentalsTypical Sequence of Installation Steps Reliability, Availability and ServiceabilityScalability PerformanceEnclosure Modules ArchitectureController Modules Disk Modules SANnet II 200 Scsi Array RAID Controller DiagramDisk Drives front view with bezel removed Power and Cooling ModulesEnclosure Management Unit Enclosure Management Unit ModulesScsi Module i.e., I/O Module Scsi ModuleTermination Module Termination ModuleController Optimization FeaturesController Redundancy Read Caching Cache ProtectionLogical Drives Write CachingDisk Redundancy Logical Drive Rebuilding Spare DisksManagement ConfigurationEvent Logs MonitoringEvent Log Window In-Band Management In-Band & Out-of-Band ManagementEvent Reporting Typical Diagnostic Service and SANscape SetupFirmware Updates Caching Detailed SpecificationsRAID5 Advanced FeaturesRAID3 Redundant Controllers RAID ExpansionData Safety User Interface Parameter Range Performance ParametersJBOD, N-RAID, RAID 0, RAID 1, RAID 1+0, RAID 3, RAID Ansi GlossaryCispr CLIFRU FC-ALGbic HBAIops IECJbod LANPID NvramRAID RASScsi SCASES SIDXOR WWN