Kenmore 153.31242 manual AIR in HOT Water Faucets

Page 20

Smelly water may be eliminated or reduced in some water heater models by replacing the anode rod (s) with one of tess active material, and then chlorinating the water heater tank and all hot water lines. Contact the local Sears Service Center for further information concerning an Anode Replacement Kit #9001453 and this Chlorination Treatment. Anode replacement and

chlorination of the tank are not covered by the water heater's limited warranty.

If the smelly water persists after the anode replacement and chlorination treatment; then you should consider chlorinating or aerating your water supply.

Do not remove the anode leaving the tank unprotected. By doing so, all warranty on the water heater tank is voided.

"AIR" IN HOT WATER FAUCETS

Before removing any access panels or servicing the water heater, make sure the electrical

supply to the water heater is turned "OFF".

Failure to do this could result in death, serious bodily injury, or property damage.

1.Before beginning, turn "OFF" electrical power supply to the water heater.

Explosion Hazard

• Flammable hydrogen gases may be present.

• Keep all ignition sources away from faucet when turning on hot water.

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these conditions, we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there wilt probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open.

RUMBLING NOISE

In some water areas, scale or mineral deposits wilt build up on your heating elements. This buildup wilt cause a rumbling noise. Follow Element Cleaning/Replacement instructions to clean and replace the elements.

HIGH TEMPERATURE SHUT OFF SYSTEM

The water heater has a high limit shut off system with a reset button located on the thermostat.

Follow the resetting instructions which refer to the high limit behind the access panel.

NOTE: If your water heater is connected to an "Off Peak" Clock, and uses the "3 wire lead" wiring diagram in the Wiring Diagram section, then the water heater wilt have a high limit on both the lower thermostat. Follow the instructions to reset the high-limit behind the lower access panel.

FIGURE 44.

2.Remove the screw securing the access panel, then remove the panel.

3.Fold the insulation back to expose the thermostat.

4.Reset the high limit by pushing in the red button marked "RESET".

BUTTON

_ RESET

FIGURE 45.

5.Replace the insulation so that it completely covers the thermostat and element.

6.Replace the access panel.

7.Turn "ON" electric power to the water heater.

If the high limit must be reset again, call Sears Service Department to find out why the high limit turned "OFF" the electric power

NOT ENOUGH OR NO HOT WATER

1,

In a new installation, the water heater may not be properly

 

 

connected. Make sure the cold water supply valve is open.

 

Review and check piping installation. Make sure that the

 

cold water line is connected to the cold water inlet to the

 

water heater and the hot water line to the hot water outlet

 

on the water heater.

2O

Image 20
Contents 0Qus Use & Care GuideTo avoid possible Injury or deathDeath or injury PotentiallyFire Hazard / Electric Shock Hazard Improper installation and use may result in property damageExplosion Hazard Year Limited Warranty on Water Heater Safe Installation USE and Service General ServiceItisstronglysuggestedthatthisnewwaterheaterbe BySearsauthorizedcontractorsBasic Tools Additional Tools Needed When Sweat SolderingMaterials Needed Removing the Old Water Heater MineralBuilduporSedimentMayAccumulate Facts to Consider About the LocationInsulation Blankets Water PipingHOTTERWATERCANSCALDWaterheatersareintended Valve and Pipe InsulationTemperature-Pressure Relief Valve BeremovedfromitsdesignatedopeningnorpluggedEfLever Explosion HazardProperty Damage Hazard WiringFilling the Water Heater Wiring Diagram Temperature Regulation Temperature SettingsThermostat Adjustments ThermostatsTemperature-Pressure Relief Valve Operation Anode Rod InspectionDraining and Flushing Burn hazardFill tank with water before operation Thermostat Removal/ReplacementElement Cleaning/Replacement ET,W =1t,i Fire Hazard Electric Shock HazardContact Sears Repair Services at 1-800-4-MY-HOME Drain Valve Washer ReplacementService Thermal Expansion Tank Specifications Expansion Tank Sizing ChartStart Up Conditions Operational ConditionsAIR in HOT Water Faucets Water is TOO HOT Improper installation and use may result in property damage Key Model No 153.312420For troubleshooting, product manuals and expert advice LE-FOYER MSU-HOGAR Call anytime, day or night U.S.A. and Canada

153.31242 specifications

The Kenmore 153.31242 is a reliable and efficient air conditioner that combines advanced technology with user-friendly features, making it a popular choice for many homeowners. This model is particularly recognized for its versatility in cooling, perfect for various room sizes and settings, ensuring that users can find optimal comfort at home.

One of the standout features of the Kenmore 153.31242 is its impressive cooling capacity. With a BTU rating suitable for medium to large rooms, it can effectively lower the temperature even on the hottest days. Its ability to quickly cool a space makes it ideal for summer months, allowing users to escape the heat without compromising comfort.

The unit employs a powerful compressor and a fan system designed to distribute air evenly throughout the room. This technology ensures consistent temperature control, eliminating hot spots that are common in less efficient models. Additionally, the air conditioner features multiple cooling speeds and a programmable timer, giving users the flexibility to customize their cooling preferences.

Energy efficiency is another critical characteristic of the Kenmore 153.31242. It is equipped with an Energy Efficiency Ratio (EER) that exceeds the minimum federal standards, consuming less power while effectively cooling the space. This efficiency not only reduces energy costs but also contributes to environmental sustainability, making it an eco-friendly choice.

Moreover, the Kenmore AC unit includes a user-friendly control panel with an easy-to-read display. This panel often incorporates remote control functionality, allowing users to adjust settings from the comfort of their couch or bed. Many models also offer compatibility with smart home systems, providing remote management via mobile devices.

The Kenmore 153.31242 is built with durable materials designed to withstand the test of time. Its robust design emphasizes low maintenance, with washable filters that keep the air clean and reduce allergens, enhancing indoor air quality.

In summary, the Kenmore 153.31242 stands out for its powerful cooling capabilities, energy efficiency, and user-centric features. Combining modern technology with practical functionality, this air conditioner is an excellent choice for anyone looking to maintain a comfortable living environment.