Chapter 2 | Connection and Setup |
|
|
Network Wiring
Copper Wiring
•Use a minimum of CAT5E or CAT6 network cable
•Maximum cable length is 100 meters
•Maximum cable length with POE is 50 meters.
Copper Connection
•Use T568B or equivalent connectors when wiring your system. This view shows the color code as viewed from the front of the female socket or the rear of the male connector.
•Crossover wiring is not needed; the Momentum network interface compensates for
Pin T568B (female)
1Orange/White
2Orange
3Green/White
4Blue/Power
5Blue/White
6Green Receive
7Brown/White
8Brown Power
Description
T568B
Fiber Connection (Optional)
The Momentum Fiber option uses ST style connectors and operates at 850nm. The system is fully IEEE 802.3z Gigabit Ethernet compliant. The following are performance based on the cable type:
220 meter distance use 62.5/125um MMF 160MHz Km Cable
275 meter distance use 62.5/125um MMF 200MHz Km Cable
500 meter distance use 50/125um MMF 400MHz Km Cable
550 meter distance use 50/125um MMF 500MHz Km Cable
Momentum mo8me Manual | 11 |