Chapter 2 | Connection and Setup |
|
|
Setting Device Before Use
THE FOLLOWING FRONT PANEL SETTINGS MUST BE CONFIGURED PRIOR TO USING MOMENTUM. The IP setting is required only if the unit is to be controlled with a PC or external controller.
A detailed description of control functions can be found in chapter 3, pages
Start Channel Route
The mo8me does not require a start channel. The unit is shipped with routing channels
The start channel, in this case, will be the first of the selected sixteen inputs. While in resting or
IP Address
An IP address will need to be set only if the Momentum network will be controlled with a PC or external controller. The IP address defaults to 192.168.1.1. When in the idle menu state, pressing the F1 key will flash the current ad- dress. The number shown is the LSB of the IP address (192.168.1.[LSB]). If the network is to be controlled with a PC, each mi8 unit will need a unique IP address. All IPs need to be set manually on the individual unit.
It is best practice to keep the input unit’s IP address sequential with its channel. In other words, Chn
Sample Rate
PLEASE NOTE: The mo8me can ONLY be set at a sample rate of 48k. All other network devices must also be 48k. A setting for sample rate 96k has been added for future use, but it is not available at this time. You will be unable to execute and save this sample rate change.
Momentum mo8me Manual | 14 |