Momentum Sales & Marketing MO8 manual Connection and Startup, Power

Page 9

Chapter 2

 

Connection and Startup

2

Power

Use only with the power supplies provided by Pro Co Sound.

OR

Use only 802.3af PoE power supplies.

The Momentum output unit requires 48VDC power to operate. There are two ways to power the unit:

1.Use the Pro Co One Spot power supply. It is shipped with the unit and allows the powering of only one device. An alternative to the One Spot is the Multi Unit Power Supply (MUPS). This power supply comes with three jumper cables that will allow up to four units to be linked together and powered by one MUPS. The MUPS is an additional option and must be ordered separately.

2.Use a standard Gigabit IEEE 802.3af PoE network switch and power up through the Ethernet cable. The POE switch must be capable of 15Watts per Ethernet port.

 

 

 

 

 

 

Ethernet

port

One Spot or MUPS power supply ports

Momentum mo8 Manual

9

Image 9
Contents Mo8 Warranty Table of Contents Use Extreme Caution Welcome Momentum System FeaturesMo8 Enclosure Rear Panel with Contractor Panel Rear PanelConnection and Startup PowerCopper Wiring Network WiringCopper Connection Fiber Connection OptionalOne to One Connection Network ConfigurationsStage 48 x 8 Typical Snake SystemChn=009 Adr=002 48 x8 With Split Network SystemSetup Using the Control PanelNetwork Clock Sync Start Channel Route Setting Device Before UseIP Address Sample RateF1 and F2 Functions Control Panel FunctionsDescription of Functions Channel Start Route Off or Mo8 Specifications