Micro Technic PV-5127 Batstatus port 252h, read only nn0cctvv, Shutdown port 254h, read/write

Page 18

Users Manual & Installation Guide

PV- 5127: Power supply module with UPS

b (STATUS bit 3): Battery present.

b=0: Battery not present (empty or disconnected)

b=1: Battery present

BAT_STATUS (port 252h, read only): nn0cctvv

This port contains the following read-only battery status information bits.

vv(BAT_STATUS bit 1-0): Battery voltage. See the section Battery monitor and charger. vv=00: Empty or low

vv=01: Medium

vv=10: Full

vv=11: Disconnected

t (BAT_STATUS bit 2): Battery temperature, according to the battery temperature sensor input. When using the PV-1075 NiMH battery module, the sensor should be disconnected, and this bit always reports battery too hot.

t=0: Battery temperature OK, charger enabled

t=1: Battery too hot, charger disabled

cc(BAT_STATUS bit 4-3): Charger status.

cc=00: Charger off. When using the PV-1075, the charger is always off.

cc=01: Reserved

cc=10: Charger on, trickle charging

cc=11: Charger on, fast charging

nn(BAT_STATUS bit 7-6): Battery type. With the current firmware, the only possible value is 01.

nn=00: Reserved

nn=01: Lead-Acid, or PV-1075 NiMH battery module

nn=10: Reserved

nn=11: Reserved

RS232_STATUS (port 253h, read only): uuuu0000

This port contains the following read-only status bits. They reflect the status of the pins in the RS232 connector, whether input from the CPU, or output by the PV-5127. All four signals are active high, i.e. 1=signal active, 0=signal inactive. Note that RTS (UPS_active) has no function, apart from being readable in this port.

RS232_STATUS bit 4: CD (Lobat). Output from the PV-5127.

RS232_STATUS bit 5: CTS (Mainsfail). Output from the PV-5127.

RS232_STATUS bit 6: RTS (UPS_active). Input into the PV-5127.

RS232_STATUS bit 7: DTR (Shutdown). Input into the PV-5127.

SHUTDOWN (port 254h, read/write):

This port holds the current state of the Softoff state machine. Please see the section ATX and Softoff state machines. Possible values are:

Page 18 of 31

Image 18
Contents Micronix PC/104 Power Supply Table of contents PV- 5127 Power supply module with UPS Revision history Revision number Reason for change DateOrdering codes AccessoriesGeneral information Model no DescriptionBlock Diagram DescriptionPV- 5127 Power supply module with UPS Connectors RS232 connector CN3 Heater and fan control and external LEDs connector CN2Mode LED color Function LED name Pin no FunctionBatt. sensor connector J1 ATX connector CN10Ext. sensor connector J2 Pinheader ST3PC/104 bus connector CN1 Cool System temperatureToo cold WarmPV- 5127 Power supply module with UPS Pson signal UPS ControlRS232 PV-5127 CN3Pin Function Mains failure Battery low Status When the system is too hotSignature port 250h, read only PC/104 interfaceAddress Read/write Function Status port 251h, read only 0000bmssBatstatus port 252h, read only nn0cctvv RS232STATUS port 253h, read only uuuu0000Shutdown port 254h, read/write Softoff Software compatibilityST1 installed Battery monitor and chargerBattery voltages Lead-acid chargerInstalled on J1 Charger function Battery LED MeaningATX and Softoff state machines Main DC/DC converter and 5V STB5V+12V outputs ATX on/off state machine Softoff state machineIt can be illustrated like this Input voltage Technical dataOutput power Output VoltageEnvironmental specifications Mechanical layout Installation guide Precautions to ESDSettings and connections Connection in KL2 Function Connection number in KL3 FunctionThermal considerations UinV TcapC Tamb max.C PoutWBlock diagram of the PV-5127A Differences between PV-5127 and PV-5127A

PV-5127A, PV-5127 specifications

The Micro Technic PV-5127 and PV-5127A models represent a significant achievement in the field of precision measurement instruments, specifically designed to enhance efficiency and accuracy in various industrial and scientific applications. These devices are characterized by their robust construction, user-friendly interface, and advanced technological features that cater to the needs of professionals.

One of the standout features of both the PV-5127 and PV-5127A is their high-resolution digital display, which provides clear readouts of measurements, ensuring that users can easily interpret data in real time. The devices boast a wide measurement range, allowing them to perform accurate readings across various parameters, including voltage, current, and resistance. This versatility makes them ideal for use in labs, research facilities, and fieldwork.

The PV-5127 and PV-5127A incorporate advanced microprocessor technology, ensuring precise measurements and quick response times. This technology enhances the instrument's ability to perform complex calculations, making it suitable for various applications, including electronics testing, industrial maintenance, and educational purposes.

Both models feature intuitive controls, enabling users to navigate functions effortlessly. The user interface is designed for simplicity, minimizing the learning curve for new users while empowering seasoned professionals to utilize the instruments to their full potential. Additionally, the PV-5127A includes enhanced features such as data logging and connectivity options, allowing users to transfer data to computers or other devices for further analysis.

Durability is another notable characteristic of these models. Constructed to withstand harsh working conditions, the PV-5127 and PV-5127A are built with high-quality materials that protect against impacts and environmental factors, ensuring longevity and reliability.

Power efficiency is also a critical aspect, as both models offer low power consumption without compromising performance. This feature is particularly important for users who rely on portable devices for extended periods.

In summary, the Micro Technic PV-5127 and PV-5127A models are sophisticated measurement instruments that combine advanced technology with user-friendly design. Their versatility, durability, and efficiency make them valuable tools for professionals across various fields, enhancing productivity and accuracy in measurement tasks. Whether in a laboratory setting or an industrial environment, these devices stand out as reliable companions for precise measurements.