Micro Technic 1800 Series, PV-1700 UPS signals CN7, PV-1800 register interface, Base address

Page 14

UPS signals (CN7)

Modules with onboard DC/DC converter has signals that, combined with external circuitry, can be used to implement a UPS function. There is an input for turning off the 20W power supply (SWITCHER_OFF), two status inputs (UPS_STATUS1 and UPS_STATUS2), and an output (UPS_PWROFF) that can tell the external circuitry to turn off power after a programmable delay.

Connector layout:

Pin no Name

1GND

2*

3*

4*

5*

6UPS_PWROFF

7+5V

8UPS_STATUS2

9UPS_STATUS1

10 SWITCHER_OFF

￿

￿￿￿￿￿ ￿

* = do not connect, for internal factory use.

PV-1800 register interface

All modules, except PV-1730 has a register interface with three blocks of I/O ports: the modem UART, the external RS232

UART and the internal registers. The UARTs are 16C550 compatible and use eight I/O ports each.

The base addresses of the modem UART and external RS232 UART are configured on configuration jumper 1,2,3 and 4,5,6 respectively, see the table printed

on the board. The IRQ of both UARTs are configured on the IRQ jumpers. You cannot use the same IRQ for both UARTs.

Base address

Configuration jumper 7, 8 configure the base address of the sixteen internal registers. This table is also printed on the board.

ST1

Base address

7

8

Registers

0

0

200h

0

1

220h

1

0

300h

1

1

320h

￿ ￿ ￿ ￿ ￿ ￿ ￿ .

￿￿%- ￿￿%-#￿￿'$

Page 14 / 21

Image 14 Contents
Micronix PC/104 Power Supply Table of contents General information Analogue configurationsDigit Configuration Ordering codesAccessories Model no Ordering code DescriptionBlock diagram DescriptionConnectors Modem Power SupplySetting up the module Modem status LEDSIM card Modem AUX connector CN3Pin no Name Signal name in modem Pin no CDB-9F Base addressRS232 port CN6 Setting up RS232RS232 connector CN6 Pin no CN9 Differential measurement ConfigurationAnalogue inputs CN5 Pin no NameMode Function Digital inputs CNDigital outputs CN2 Base address UPS signals CN7PV-1800 register interface Address Access Name Function RegadchiPage Conversion Technical data Environmental specifications Digital outputsMechanical Layout Settings and connections Installation guidePrecautions to ESD Factory settings