Micro Technic PV-1700, 1800 Series user manual Digital outputs, Environmental specifications

Page 19

Users Manual & Installation Guide

 

 

PV- 1800: Power supply module with GSM MODEM

 

 

 

Max input voltage

30V, current limiting resistor = 3.32kohm / 250mW

 

Counter input

DI0 can act as a 16-bit up-counter by counting positive or

 

 

 

negative edges (configurable)

 

 

 

DI0 and DI1 can act as a 16-bit quadrature counter.

 

Max counting rate

10kHz

 

Connector type

10 pin box header

 

Digital outputs:

 

 

Number of channels

7 isolated PNP outputs

 

Max load current

0.5Adc, load current external delivered,

 

 

 

total current must not exceed 1.5Adc.

 

Max voltage

30Vdc

 

Protection

Snubber diode at each output

 

Connector type

10 pin box header

 

Environmental specifications:

 

 

Operating temperature:

-20ë to +70ëC

 

Storage temperature:

-40ë to 85ëC

 

Humidity:

20 to 90% non-condensing

 

Cyclic humidity:

ETS 300 019-2-5 or equal

 

Vibration:

10-1000 Hz Sinus and random @ 1-1,5G RMS

 

Sustained vibration:

EN 60068-2-34 & EN 60068-2-36

 

Shock

IEC 60068-2-27 & IEC 60068-2–29

 

Size (W x L x H)

90 x 96 x 14 mm – see next page

 

Weight:

116 g (excl. packaging)

 

*for details refer to SonyEricsson’s documentation:

GM47_48 Guidelines and

GM47_48 Integrators Manual

Page 19 / 21

Image 19
Contents Micronix PC/104 Power Supply Table of contents Ordering codes Analogue configurationsDigit Configuration General informationModel no Ordering code Description AccessoriesDescription Block diagramConnectors Modem status LED Power SupplySetting up the module ModemBase address Modem AUX connector CN3Pin no Name Signal name in modem Pin no CDB-9F SIM cardRS232 connector CN6 Setting up RS232RS232 port CN6 Pin no CN9 Pin no Name ConfigurationAnalogue inputs CN5 Differential measurementDigital inputs CN Mode FunctionDigital outputs CN2 PV-1800 register interface UPS signals CN7Base address Regadchi Address Access Name FunctionPage Conversion Technical data Digital outputs Environmental specificationsMechanical Layout Factory settings Installation guidePrecautions to ESD Settings and connections