Specifications

The machine is adaptive in following situation Cautions

Manual background All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.

Manual background Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Manual background Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.

Manual background Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1. Applicable ambient temperature range:

Indoor

Maximum:D.B/W.B

32 C/23 C

Minimum:D.B/W.B

18 C/14 C

Cooling

Outdoor

Maximum:D.B

43 C/26 C

Minimum:D.B

10 C/6 C

 

Heating Indoor

Maximum:D.B

27 C

Minimum:D.B

20 C

 

Outdoor

Maximum:D.B/W.B

24 C/18 C

 

Minimum:D.B/W.B

-15 C

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC or T 25A/250VAC. Please check the circuit diagram about the fuse replaced.

4.The wiring method should be in line with the local wiring standard.

5.The power cable and connecting cable are self- provided. The requirement of the power cable to the outdoor unit: H05RN-F 3G 4.0mm2

Model

Cable type

 

 

AU182XFERA

H05RN-F 3G 4.0mm2

AU222XFERA

 

 

 

All the cables shall have got the local authentication certificate.

6.The breaker of the air conditioner should be all- pole switch; and the distance between its two contacts should be no less 3mm. Such means for disconnection must be incorporation in the fixed wiring.

7.The waste battery shall be disposed properly.