Haier AU182XFERA Wiring work, Correct Pressing, Wrong Pressing, Terminal, block, Pressing Clamps

Models: AU182XFERA AU222XFERA

1 18
Download 18 pages 12.25 Kb
Page 13
Image 13
 Wiring work
Wiring Method for Ring Terminal Block

Correct Pressing Wiring work

1.Electric wiring Note:

Wrong Pressing The air conditioner must use special circuit , and wiring by the qualified electrician according to the wiring rules specified in national standard.

Terminal The grounding wire and the neutral wire shall be strictly separated. Connect the neutral wire with grounding wire is incorrect.

block The electric leakage breaker must be installed.

Pressing All the electric wire must be copper wire.When wiring,there shall keep a proper distance between the power line and communication wire to avoid twist together. Otherwise,signal disturbance will occur,and the air conditioner can not operate normally. Power supply: 1PH, 220-230V~, 50Hz.

Manual background The wiring method of power line is Y connection. If the power line is damaged, in order to avoid risk of electric shock, it must be replaced by the manufacturer or its repair center or other similar qualified person.The connecting cable must be shielded.

Manual background Fuse: T3.15A 250VAC T25A 250VAC (Please check with the outdoor unit wiring diagram.)

Manual background Please check the circuit diagram about the fuse replaced.

2. Wiring method

Manual background Wiring method of orbicular terminals For the connection wire with orbicular terminals, its wiring method is as shown in the right figure: remove the connecting screw, put the screw through the ring on the

end of the wire, then connect to the terminal block and fasten screw. Manual background Wiring method of straight terminals

For the connection wire without orbicular terminals, its wiring method is: loosen

the connection screw, and insert the end of the connection wire completely into the Terminal block, then fasten the screw. Slightly pull the wire outwards to confirm it is firmly held.

Correct Pressing

Wrong Pressing

 

Terminal

 

block

Pressing

Clamps

Manual background Crimp connection method for wires without terminals

Connect the wire with same diameter to the two sides of the terminal

Do not connect the wire with same diameter to the same side

Do not connect the wire with different diameters

11

Page 13
Image 13