Micro Technic PV-1800 user manual Installation guide, Precautions to ESD, Settings and connections

Page 19

Users Manual & Installation Guide

PV- 1800: Power supply module with GSM MODEM

Installation guide

Precautions to ESD

Please note that the Micronix PV modules must be handled with respect to ESD (Electrostatic Discharge). Electrostatic Discharge to the PV modules must be avoided.

Before removing the module from the protection bag, the user must be discharged using a grounded wrist ribbon.

Settings and connections

A typical setup procedure involves these steps:

1.Perform settings of:

Base address. (Regs.).

Port number for COM_A (modem).

IRQ number COM_A (modem).

Port number for COM_B (RS232).

IRQ number for COM_B (RS232).

2.Place PV1800 in the PC/104 stack.

3.Connect interface cables: Analogue, digital etc.

4.Place a SIM card in the SIM card connector.

5.Connect the antenna cable to the MMCX-connector at the modem.

6.Connect the power cable (24V DC) at KL1.

Factory settings

The default jumper setting depends on the model you have purchased.

Factory settings, PV-1800:

￿ ￿ ￿ ￿ ￿ ￿ ￿ .

￿￿%- ￿￿%-#￿￿'$ ￿￿ ￿￿ ￿￿ ￿￿ + ￿ ￿ ￿ ￿

￿,- ￿,-#

Registers base address: 200h

Modem port: 3E8 (COM3)

Modem IRQ: 10

RS232 port: 2E8 (COM4)

RS232 IRQ: 12

Factory settings, PV-1820 / PV-1830:

￿￿

￿,- ￿,-#

￿ ￿ ￿ ￿ ￿ ￿ ￿ .

￿￿%- ￿￿%-#￿￿'$ ￿￿ ￿￿ ￿￿ + ￿ ￿ ￿ ￿

Registers base address: 200h

Modem port: 3E8 (COM3)

Modem IRQ: 10

Page 19 / 19

Image 19
Contents Micronix PC/104 Power Supply Table of contents Ordering codes Analogue configurationsAccessories General informationDescription Block diagramConnectors Modem status LED Power SupplySetting up the module ModemBase address Modem AUX connector CN3Pin no Name Signal name in modem Pin no CDB-9F SIM cardPin no CN9 Setting up RS232RS232 connector CN6 RS232 port CN6Pin no Name ConfigurationAnalogue inputs CN5 Differential measurementCounter inputs Mode FunctionDigital outputs CN2 PV-1800 register interface UPS signals CN7Base address Regadchi Address Access Name FunctionPV- 1800 Power supply module with GSM Modem Conversion Technical data Digital outputs Environmental specificationsMechanical Layout Factory settings Installation guidePrecautions to ESD Settings and connections