Micro Technic PV-1800 Power Supply, Modem status LED, Setting up the module, Modem LED Status

Page 6

Users Manual & Installation Guide

PV- 1800: Power supply module with GSM MODEM

￿￿)=&￿6￿5￿>￿￿￿8￿*0￿￿

Power Supply

The on-board power supply consists of a synchronous step-down switching regulator with an efficiency of 85-95%, depending on input voltage and load current. At nominal input voltage (24V DC) and a load current of 2A the efficiency is 92%. A green status LED, placed on the rear side of the PCB, is on when the +5V is present.

￿

￿￿￿￿￿ ￿

The connector for the power input is a 2 pole pin header from Molex. The mating part for this connector is Molex 10-17-3020 with 2 crimp terminals – Molex 2478.

Modem

The modem unit used in the PV-1800 module is a Sony Ericsson GM47 which is a GSM dual band product for 900/1800 MHz. The unit is placed in a 60pin socket and secured by two M2 screws and nuts.

Modem status LED

A yellow status LED is connected to the modem. This LED is placed on the rear side of the PCB. The LED has this function:

%￿0￿￿￿$￿*￿￿$

Modem LED

Status

Off

Modem off

On, steady

Power on, not connected to network

On, flashing

Power on, connected to network

Setting up the module

All communication between the modem and the CPU is done through an on-board 16C550 compatible UART. The COM port and the IRQ used for the modem are set by two jumper blocks. The address is set by one to three jumpers in positions 1 to 3 in section COM_A.

The table shows how different COM ports can be configured.

Page 6 / 19

Image 6
Contents Micronix PC/104 Power Supply Table of contents General information Analogue configurationsAccessories Ordering codesBlock diagram DescriptionConnectors Modem Power SupplySetting up the module Modem status LEDSIM card Modem AUX connector CN3Pin no Name Signal name in modem Pin no CDB-9F Base addressRS232 port CN6 Setting up RS232RS232 connector CN6 Pin no CN9Differential measurement ConfigurationAnalogue inputs CN5 Pin no NameMode Function Counter inputsDigital outputs CN2 UPS signals CN7 PV-1800 register interfaceBase address Address Access Name Function RegadchiPV- 1800 Power supply module with GSM Modem Conversion Technical data Environmental specifications Digital outputsMechanical Layout Settings and connections Installation guidePrecautions to ESD Factory settings