Marshall electronic V-R241-DLW manual Tally Source, Tsl

Page 24

. TSL v4.0

Use the TSL v4.0 protocol setting when controlling the IMD from a TSL tally controller, or other controlling device which utilizes the TSL v4.0 protocol. The IMD # must be set for each screen in conjunction with the controlling device.

MEI

Use the MEI protocol setting when controlling the V-R241-DLW using the Marshall Network Controller box. This protocol allows remote control of all features on the V-R241-DLW, including marker setup, video configuration, system configuration, and image adjustments (brightness, contrast, etc.). The IMD #, IMD Group #, and Baud Rate parameters must be set in conjunction with the Network Controller Box.

MEI-Image Video

This protocol setting accepts Image Video commands via MEI protocol, for use when an Image Video controller is connected to the Marshall Network Controller box.

Tally Source

The V-R241-DLW OSD tally can be controlled in a variety of different ways. Use the Tally Source setting to choose how tally is controlled:

Standard

Use the Standard setting to control tally via contact closure on the HD-15 tally interface.

Image Video HW

Use the Image Video HW setting to control Image Video tally states via contact closure on the HD-15 tally interface. Contact closure of the Red pin corresponds to Image Video Tally 1, and the Green pin maps to Image Video Tally 2. Contact closure (ground) corresponds to a LOW state, and open circuit corresponds to a HIGH state. This mode requires the IMD Tally Mode parameter to be set. Consult Image Video documentation for further information.

Image Video 422

Use the Image Video 422 setting to control Image Video tally states via the Image Video serial protocol. OSD tally will be disabled in this mode, as Image Video tally states are manifested in the text color and other

parameters. This mode requires the IMD Tally Mode parameter to be set. Consult Image Video documentation for further information.

Standard + IV422

Use the Image Video 422 setting to control Image Video tally states via the Image Video serial protocol, while controlling OSD tally using contact closure on the HD-15 tally interface. This mode requires the IMD Tally Mode parameter to be set. Consult Image Video documentation for further information.

TSL/MEI 422

Use the TSL/MEI 422 setting to control OSD tally via the TSL or Marshall serial protocols.

24

Image 24
Contents Operating Instructions Model No. V-R241-DLWThis page intentionally left blank Contents Features 1920 x 1200 Full Resolution 24 PanelInstallation and Initial Setup InstallationConnections, Power-On and Initial Setup UnpackingFront Panel Features Power ButtonRear Panel Features RS-422/485 Serial InterfaceCompatible Input Formats Following SDI standards are supported by the V-R241-DLWDLW Monitor Layouts Waveform Monitor Mode Full Screen Video Mode On-Screen Menu Marker Setup Submenu On-Screen MenuMarkers Marker Background Center MarkerVideo Config Submenu Monochrome ModeBlue-Only Mode Pixel-to-Pixel Mode Aspect Ratio SettingsAnalog Phase DVI-Analog or VGA input only DVI-A CSC Mode DVI-Analog input onlyDVI-D CSC Mode DVI-D input only Curtain ColorColor Config Submenu System Config SubmenuHdmi CSC Auto Hdmi input only, via the DVI-I interface Saving and Loading User Presets User-Definable Function ButtonsOSD Config Submenu IMD StateStatus Display OSD Tally LED TallyAnc. Timecode OSD Timeout Audio MonitorCC Monitor Closed Captioning IMD Config Submenu OverviewIMD ID # IMD Group #Tally Source TSLIMD Fixed Config Submenu Service Closed Captioning SubmenuIMD Fixed String ModeWaveform Mode Wave/Vector SubmenuWaveform Scale Colorize WaveformAncillary Submenu DID/SDID Service Submenu Software Version DisplaySpecifications PanelDimensions Maintenance WarrantyScreen Cleaning Burn-In WarningThis page intentionally left blank 2010-1229