Perlick Installation and Operating Instructions, Model Nos DC72S DC84S DC96S, End View TopView

Page 2

Installation and Operating Instructions

Sizes and Specifications, Concessionaire Dispensers

Model Nos.

 

dC72S

dC84S

dC96S

keg capacity

2 Keg

3 Keg

4 Keg

CABINET

Length Ins. (mm)

72” (1829)

84” (2134)

96” (2438)

Dimensions

 

 

 

 

 

Depth Ins. (mm)

243/4” (629)

243/4” (629)

243/4” (629)

 

w/o Bumpers

Height Ins. (mm)

341/2” (876)

341/2” (876)

341/2” (876)

No. of dispensing heads

1

1

2

 

No. faucets

 

2

2

2

 

condenser unit h.p.

1/4

1/3

1/3

 

running load - amps

5.9

7.5

7.5

 

Ship wt lbs. (kg)

445 (202)

505 (229)

545 (247)

 

Interior

 

Door sill: High strength polyethylene. Door pan and ceiling: High strength polystyrene.

 

 

Floor pan: Satinless steel. Walls: Galvanized steel.

 

 

exterior

 

All Models: The top is stainless steel. The back, front and sides are stainless steel. Bottom is

 

 

galvanized steel. Doors and grilles are stainless steel.

 

 

 

 

 

 

 

Refrigeration

R-134a capillary tube-type. Aluminum fin and copper tube evaporator, epoxy coated coil. Forced air

 

 

into dispensing head. Adjustable temperature control. Self-defrosting. Pull-out condensing unit for

 

 

service and cleaning.

 

 

 

 

 

 

 

 

 

Ventilation

 

Front ventilated.

 

 

 

electrical

 

115 Volt, 60 Hz., 1 Phase AC. Furnished with three prong, six foot NEMA5-15P cord.

 

 

Contact Perlick for other voltage/frequency requirements.

 

 

 

 

 

 

 

 

Plumbing

 

Evaporator condensate has been plumbed to a condensate pan located in the compressor housing.

Insulation

 

Foamed-in-place polyurethane; 2” walls, 11/2” top and floor.

 

 

 

 

 

 

 

 

OPTIONAL ACCESSORIES

• Keg Couplers

• Faucet Locks

 

 

 

 

• Regulators

• Optional Dispensing Heads

 

 

 

 

 

 

 

 

NOTE: This equipment is intended for the storage and display of non-potentially-hazardous bottled or canned products only.

Form No. Z2283 Rev. 06.14.10

End View

TopView

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

2

Image 2
Contents Model NOS End View TopView Installation and Operating InstructionsModel Nos DC72S DC84S DC96S Preparing the Cabinet for Use Concessionaire Dispensers Important Be sure to close this valve when untapping keg Installation and Tapping Concessionaire DispensersConnecting the Keg Coupler Tapping a Single Valve Keg SankeyReplacing CO2 Gas Cylinder Connecting the Regulator to the CO2 CylinderAdjusting the CO2 Gas Flow Proper CO2 HandlingAdjusting the Temperature TemperatureRefrigeration and Temperature Control Draft Beer Information Concessionaire DispensersCleaning the Condenser Cleaning the Beer System Concessionaire DispensersCleaning the Cabinet BacteriaPouring a Perfect Glass of Beer Concessionaire Dispensers StepFlat Beer Trouble Shooting Concessionaire DispensersBeer Service Problems Wild Beer Cloudy BeerDC72S DC84S DC96S Condensing Units Replacement Parts Concessionaire DispensersEvaproator Assembly Micellaneous Wiring Diagram Concessionaire DispensersFor Single Valve Keg Coupler Series D Part DescriptionReversing Door Hinge Tools Required