VGA cable or purchase another type of VGA cable and set an internal jumper in Jiva TP/LT-5600 or Jiva TP/LT-5800 to supply the required power through the VGA connector. Do not connect other monitor to this port before the power in this port is disabled.
TOP MOUNT CUSTOMER DISPLAY
Please follow the instructions on the manual that comes along with the top mount customer display PD302 when it is installed.
SERIAL PORTS – COM1/2/3/4
In Jiva TP/LT-5600 / Jiva TP/LT-5800, there are 4 serial ports available except those models using RS232 touch interface (Infra Red type touch panel). All the serial ports can supply a +5 V DC through pin 9 after proper jumper setting change. All 4 ports are standard RS232 serial ports as status at delivery.
When a serial Modem is to be used in Jiva TP/LT-5600 or Jiva TP/LT-5800, it is most recommended to use COM2 or COM3 port for this purpose. In this way any hardware resource conflict is eliminated and the MODEM ring up function can be supported. For Infra Red type touch control models (it uses RS232 interface), COM4 is occupied and covered. Please never try to open the cover. Otherwise the product warranty is voided.
SOUND PORTS
The audio port on Jiva TP/LT-5600 / Jiva TP/LT-5800 supports a Microphone in and a line out jacks. The internal audio output port supports line output signals and requires power amplifier for connection to speaker unless the option of audio amplifier and a pair of slim type speakers built in the cable cover area are ordered at the beginning.
SYSTEM MONITOR
In the preloaded OS for Jiva TP/LT-5815, there is an embedded function that keeps monitoring the interior temperature and the fan revolution rate and regulating each required fan power to gain maximum ventilation effect with lowest possible noise. This function also safeguards the system from damage due to overheat. Once the temperature detected inside the system is found too high or when either the system
exhaust fan or CPU fan is found inoperative, one of warning messages like the picture at right will pop up. When this occurs, please close all application programs and shutdown the system immediately to prevent any further damage. Even if you don’t, it may be only