POSIFLEX Business Machines Touch Terminal, 5800, 5600 Routing the Cables, Preparing the Main Unit

Page 9

ROUTING THE CABLES

Fix this End of the Cover First

Route Cables under the Cover

Connect this End to Main Unit

This End to Other Devices

Place all the cables required for connections to the Jiva TP/LT-5600 or Jiva TP/LT-5800 except those for special application purposes into the cable passage. Insert one end of the cable passage cover under the adjacent cover plate and screw on the two screws. Be sure not to damage any of the cables during this operation.

Now, turn the adjustable stand assembly back to normal orientation and arrange all cables to come out of the area for mounting main unit from the bottom edge for ease of later operation.

PREPARING THE MAIN UNIT

On the back of the main unit, there are 4 matching pegs and a service window. Push open the service window in the direction as indicated in the picture, one can find a button cell battery socket, two 1 x 2 (JP6, 9) and two 1 x 3 headers (JP11, 16) with 1 jumper each and two 2 x 3 header (JP13, 14) with 2 jumpers each. Though it is possible that the contents in the service window may change as time develops.

Service

4 Matching

Window

Pegs

Push

 

 

 

 

Open

 

To The

 

Right

 

CAUTION

Risk Of Explosion If Battery Is Replaced By An Incorrect Type

Dispose Of Used Batteries According To The Instructions

This battery socket accepts a 3 V button cell Lithium battery (CR2032) required to support the system real time clock. The jumpers in this window are designated for VGA port and COM port power supply function. Please consult your dealer for technical support on setup of these jumpers. A new Lithium battery can support the system RTC for about 3 years. After the battery is nearly exhausted, the user must change a new battery otherwise the system RTC and system configuration setup will be lost.

Part 9

Image 9
Contents Jiva TP/LT- 5600/5800 Series Touch Terminal User’s Manual Alert to OUR Honorable Customers Daily Maintenance GuideStandard Features User’s ManualProduct Optional Items Part Opening Cable Cover Installation GuidesDisconnecting Cables Opening Stand AssemblySeparating Main Unit Cash Drawer Installing UPS BatteryPreparing the Main Unit Routing the CablesWireless Printer Installing Upgrade KITConnecting Cables Joining Main Unit and StandWall Mounting Location for Installation Operating System RecoveryIDE Cable KIT for Jiva Operating System Installation Application Environment UPS Battery optionVentilation Operating EnvironmentPower ON/OFF Power SupplyLED Indicator Hardware Power Switch Automatic Power onSoftware Support Features By RTC Alarm presetDisplay Settings LAN BootSerial Ports COM1/2/3/4 TOP Mount Customer DisplaySound Ports System MonitorPosiflex Touch Terminal Manager Mouse EmulationRS232 Touch Controller