POSIFLEX Business Machines 6800 warranty Multiple Interface Issue, Upos Concerns, Interface models

Page 19

Switch position 6 defines the parity check regulation in serial interface. In Aura-6800, it is selectable between even and none.

For switch position 7 can choice the handshaking method in serial interface. When it is set to ON, the printer transmits an “XOFF” for busy and sends an “XON” for not busy. When it is set to OFF, the printer signifies the busy status over hardware signals that can be detected by the host as “DSR” or “CTS”. When parallel interface is used, both switch positions 3 and 4 should be set to OFF.

For switch position 8, when it is set to ON, the printer responds to a carriage return command (CR code or 0Dh) with also a line feed (LF code or 0Ah) action. Then if the text editor always expresses the change to a new line with both the CR and LF codes, there will be an extra line advance than expected. However it works for some old editors that express the change to a new line with only either one of the LF code or the CR code.

The factory default for each position listed as below:

Switch 2 Position

1

2

3

4

5

6

7

8

Default setup for all Aura-

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

6800 interface models

 

 

 

 

 

 

 

 

SW3 software switch controlled the retractable function WHEN SW2-4 SET TO OFF. When this switch set to OFF, printer will enable to retract paper 6

mmbefore it start to print with the aim of reduce paper loss. In contrast, it will straight to print when this switch place to ON. Please notice that the factory default of this switch is OFF.

MULTIPLE INTERFACE ISSUE

For model Aura-6800, there is only 1 connector for host connection through RS232. For Aura-6800P, there are 2 connectors for host connection: RS232 and in addition to parallel port. For Aura-6800U, there are 2 connectors for host connection: RS232 and in addition to the USB port. For Aura-6800L, there are 2 connectors for host connection: RS232 and in addition to the LAN port. Please always connect only one interface at a time. Simultaneous multiple host connections could result in unexpected results!

UPOS CONCERNS

The UPOS compliance and WEPOS compliance ability of the Aura-6800 series dictates the printer to perform certain internal affairs such as counter

Page 19

Image 19
Contents $XUD Product Briefing Getting StartUnpacking Product Pictures OptionsTop View Bottom View Front ViewRear View Loading Paper IndicatorsWhen to Replace Paper Quick START-UPLAN Connection Connecting CablesSerial Connection Parallel ConnectionPeripheral Connection Wi-Fi ConnectionPower Connection Power OnPaper Near End Sensor Special Adjustments58mm Paper Spacing Plate Web Manager for Aura-6800L Installing DriverReset Pin Hole Paper CuttingLAN POS Printer Manager Maintenance Guide LinesPosiflex Wi-Fi POS Printer Manager for Aura-6800W Operation GuideGeneral Problems General CleaningPrint Head Cleaning Trouble ShootingPaper Jam Problems Advanced Analysis Tool Useful TipsPrinter SpecificationsPaper Power AdaptorPrinter Setup Further Technical InformationPosition DIP SwitchSwitch Baud rate setupAura -6800/P/U Switch 1 Position Default setup forSoftware switch SW2 software switch works as following Aura-6800LPrint Density SW2 PosInterface models Multiple Interface IssueSwitch 2 Position Default setup for all Aura Upos Concerns$%&*+,-!Page#20