replace the used up UPS battery at power off as soon as possible.

Emergency treatment:

The battery is constructed maintenance free and leakproof. Its storage space in HT system also provides very good protection as long as the ambient temperature remains below 30°C and the ventilation of the HT system remains free. However, should any accident happen and the sulfuric acid from the battery spills on skin or clothing, wash immediately with water. If the acid comes in contact with eyes, rinse eyes with large amount of clean water and see a doctor immediately. A larger external battery may be connected to give an extended operation. Please check your dealer about this capability when required.

WARNING:

If there are any signs of over charging or leakage of electrolyte please contact your dealer immediately

VGA Display Port

The VGA port in the HT terminal can be connected to the 10.4” rear mount optional 2nd monitor LM-2010 with appropriate power arrangement.

The video memory of this port shares from the system memory. The video memory size can be set in the BIOS CMOS setting to match the user’s application.

Serial Port – COM1

For the HT system with the UPS function, a COM1 terminator will also be supplied. Please always occupy COM1 serial port by a suitable serial device or this terminator. If this port is left vacant or connected with something like a mouse, the power switch management and the cash drawer control may fail to work correctly. An RS232 MODEM is not applicable to this port. It is recommended to use COM2.

LED INDICATORS

On bottom rim center of HT system cashier LCD panel, there are 2 LED indicators. The LED at right indicates the LAN status. When it lights up in green, the onboard LAN chip is linked. When it flashes in yellow with steady green light, data transmission in LAN is in process. The LED at left indicates Power/StandBy status. When it lights up in orange, it means that the external AC power is standing by with the system powered off. It turns into blue when the system is powered up. When the UPS battery is installed, this LED further indicates the status of system working on battery power by flashing in blue. The blue light will flash rather fast when the UPS battery approaches a fully discharged condition to remind the operator that power will soon finish. In few seconds, the whole system will soon be automatically turned off and the LED will be OFF. In case the AC power resumes during the

Part 13

Image 13
Contents HT 2212 Pro Series User’s Manual Alert to OUR Honorable Customers Daily Maintenance GuideUSER’S Manual Brief IntroductionProduct Optional Items Standard FeaturesCompact Flash Memory Card Slot Type Touch panel Option to have the set without touch panelSystem BOX Contents NON-USER-INSTALLABLE Options Installation GuidesTechnical Enhancements HALF-LENGTH PCI Extension CardWireless LAN Option Power AdaptorUPS Battery Option When the HT system is installedCustomer Display Option or 2ND Display Side Mount Upgrade KIT SD-300/BC-300/KP-200 OptionBarcode Scanner Option Programmable Keyboard & Keypad OptionPrinter Option Cash Drawer OptionControl of the COM1 serial port Operating System RecoveryOperating System Installation Using the HT System Emergency treatment LED IndicatorsSerial Port COM1 Hardware Power Switch Power ON/OFF ControlCan also be programmed to be an on only switch Software Off CommandMechanical Adjustments Emergency Power OffMain LCD Touch Monitor Display ControlsTouch terminal manager Side Mount Upgrade KIT BC-300/SD-300/KP-200Customer Display USB FAN ControlRemoving Front Cover Ventilation MaintenanceAccessing Side Ventilation Grids Cleaning for Front VentilationReplacing Front Cover Side Ventilation Grids on Chassis Cleaning for Side Ventilation