b). For CR4001/ 4101/ 4211/ 4002/ 4102/ 4212: CCBLA-196A with one 9PM and one 9PF connector.

c). For CR4003/ 4103/ 4213: CCBLA-089-1 with one 25PM and one 25PF connector.

d). For CR4004/ 4104/ 4214: The serial signal cable is already built on.

e). For CR4005/ 4105/ 4215/ CR4005-II/ 4105-II/ 4215-II: USB cable is already built on.

6.Power Source depend on model

a). For CR-4000/ 4100/ 4210: not applicable

b). For CR-4001/ 4101/ 4211/ 4002/ 4102/ 4212/ 4003/ 4103/ 4213/ 4005/ 4105/ 4215 / CR4005-II / 4105 -II/ 4215-II: Power adapter 12VAC 1.5A

c). For CR4004/ 4104/ 4214: Power connector cable and I/O bracket plate.

INSTALLATION

CR4000 / 4100 / 4210 Connect the drawer to POS system/printer as shown below:

Rear View

8P Telephone Plug

Control signal input

Ground

8P Telephone Jack

CASH DRAWER

CR4001 / 4101 / 4211

With Printer Interface

 

POS System or Printer

Output to drawer

6P Telephone Plug

1).Connect the drawer serial I/P port to the computer COM port. Connect the power adapter output to the Power Input jack

2).No other RS232C devices should be connected to the serial O/P port.

3).Set position 3 of S2 to OFF and position 4 of S2 to ON. Please refer to rear panel illustration.

CR4002 / 4102 / 4212

1).Connect the drawer serial I/P port to the computer COM port. Connect the power adapter output to the Power Input jack.

2).Other RS232C device can be connected to the serial O/P port when needed as long as the security code makes no influence to this RS232C device.

3).Set position 3 of S2 to ON and position 4 of S2 to OFF. Set S1 for security code to open cash drawer. In normal practice, the security code is suggested to be a non-displayable ASCII character, for example, a hexadecimal number between 01 to 1F. Please refer to rear panel illustration below.

CR4003 / 4103 / 4213

1).Connect the drawer parallel I/P port to the computer LPT port. Connect the power adapter output to the Power Input jack.

2).Other parallel device such as a printer can be connected to the parallel O/P port when needed as long as the Security code makes no influence to this parallel device.

3

Image 3
Contents FCC Notice Rev. CCarton Contents Model NumbersInferface Application CR4003 / 4103 InstallationCR4001 / 4101 CR4002 / 4102CR4004 / 4104 Serial O/P DB9M Serial I/P DB9F Parallel I/P DB25M GroundSW4 SW1SW2 SW3CR-4003 / 4103 Functional TestCR4000 / 4100 CR-4001 / 4101 / 4211 / 4002 / 4102 / 4212 / 4004 / 4104Specifications Power SourceElectrical Drawer Open Sense Keylock OperationStructure Security Code