POSIFLEX Business Machines CR-4000 user manual SW1, SW2, SW3, SW4

Page 5

COM1

DB9

616P PHONE JACK

 

4PIN PHONE JACK

CR4005/ 4105/ 4215/ CR4005-II/ 4105-II/ 4215-II

1). Define a drawer number for the cash drawer so that this cash drawer is going to respond accordingly in USB communication. Follow the table below for SWITCH SETTING to adjust the switch S1 according to this drawer number if it is not 7. Please note that within each system there should never be any 2 USB interface cash drawers carrying the

same drawer number.

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N4 3

2 1

 

 

 

 

 

 

S1

 

 

Connect to USB

 

AC 12V I/P

 

 

Port of Main PC

Power Jack

of CR4005/4105/4215/

USB Connector from CR4005/4105/

CR4005-II/ 4105-II/ 4215-II

 

4215/CR4005-II/ 4105-II/ 4215-II

Rear View of Model CR4005/4105/ 4215/CR4005-II/ 4105-II/ 4215-II Cash

SWITCH SETTING:

Drawer with USB Interface

 

 

 

 

 

 

 

 

 

 

Drawer

0

1

2

3

4

5

6

7

SW1

ON

OFF

ON

OFF

ON

OFF

ON

OFF

SW2

ON

ON

OFF

OFF

ON

ON

OFF

OFF

SW3

ON

ON

ON

ON

OFF

OFF

OFF

OFF

SW4

 

 

 

Reserved

 

 

 

Default setting: Drawer 7 (SW1: OFF; SW2: OFF; SW3: OFF)

2). Connect USB connector of cable coming out from the rear side of the USB interface cash drawer to USB port of main PC.

3). Check the specification of power adaptor on its nameplate. Insert the power adaptor into the correct power outlet. Insert the output plug to the jack at rear side of CR4005/ 4105/ 4215/ CR4005-II/ 4105-II/ 4215-II to supply power for drawer kickout.

4). Install the USB utility driver from Posiflex Product Information CD with Posiflex POS system or visit our web sites http://www.posiflex.com.tw or http://www.posiflextw.com or http://www.posiflexusa.com for latest updates.

5

Image 5
Contents FCC Notice Rev. CInferface Application Carton ContentsModel Numbers CR4001 / 4101 InstallationCR4002 / 4102 CR4003 / 4103CR4004 / 4104 Serial O/P DB9M Serial I/P DB9F Parallel I/P DB25M GroundSW2 SW1SW3 SW4CR4000 / 4100 Functional TestCR-4001 / 4101 / 4211 / 4002 / 4102 / 4212 / 4004 / 4104 CR-4003 / 4103Electrical SpecificationsPower Source Structure Keylock OperationSecurity Code Drawer Open Sense