Listen Technologies PS 6000 user manual System Setup, General guidelines

Page 9

Danish Interpretation Systems

User Manual

System Setup

General guidelines

Connect the PS 6000 to the various DCS 6000 units using Cat5 or Cat5e FTP or STP screened cables. Please observe the following guidelines:

Maximum cable length in one chain is 200 m without repeater. This includes interconnection cables between the units. The max. usable cable length depends on the units connected and length of feeding cables etc.

Maximum cable length in one chain when using repeaters is 650 m.

Although the output on the PS 6000 have a 125W supply, this 125W power is not all usable with long cables, as there will be a voltage drop in the feeding cable from the PS 6000 to the units connected. If the feeding cables are short and the cables

between the units are short, more units can be connected than if the feeding cable is long and/or the cables are long between the units. Please consult the next section (Max. Number of units to be connected)

If the last unit in one chain is a CS 6032 Channel Selector, this unit has to be terminated with an external termination, as the CS 6032 does not have an internal termination.

It is desirable that the square of the feeding cables especially, but also the interconnection cables are as big as possible to minimize the voltage drop in the cables. Cat 5/Cat5E cables are delivered in various gauges:

The following table is showing the Diameter/square for various AWG types

Type

Diameter

Square

AWG22

0.64 mm

0.32 mm2

 

 

 

AWG23/1

0.57 mm

0.25 mm2

 

 

 

AWG24

0.53 mm

0.22 mm2

 

 

 

AWG26

0.42 mm

0.14 mm2

 

 

 

Manual 01 18 04450

9

 

Image 9
Contents Danish Interpretation Systems Digital Conference SystemDanish Interpretation Systems List of Contents Installation precautions SafetyCleaning & Repacking WarrantyDescription of the DCS 6000 system FeaturesCentral equipment etc System componentsInterpreter equipment Voting equipmentPS 6000 Power Supply Operating instructionsSystem design Use of PS General guidelines System SetupMax. number of units to be connected CM/DM 60x0P Chairman/Delegate UnitsCM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box CM/DM 6560F Chairman/Delegate Units CM/DM 6060F/6510F Chairman/Delegate UnitsIs 6132P Interpreter Units MU 6040 C/D without connected loudspeakerCS 6032F Channel Selector w/back light on Is 6132P w/JB 6004 and LSTechnical specifications General Accessories not suppliedAppendix Technical appendix