Danish Interpretation Systems | User Manual |
Appendix
Technical appendix
Cabling
CAT5
The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.
How to wire a CAT5 (EIA
Pin | Function | Connector #1 | Connector #2 |
|
|
|
|
1 | ORG/WHT | ORG/WHT | |
2 | ORG | ORG | |
3 | +48V | GRN/WHT | GRN/WHT |
4 | 0V | BLU | BLU |
5 | 0V | BLU/WHT | BLU/WHT |
6 | +48V | GRN | GRN |
7 | Outgoing - | BRN/WHT | BRN/WHT |
8 | Outgoing + | BRN | BRN |
Note. If other colour codes are used then the four pairs are connected as follows:
Pair 1: Pin 1 & 2
Pair 2: Pin 3 & 6
Pair 3: Pin 4 & 5
Pair 4: Pin 7 & 8
The phase of the pairs must be correct and the wiring spec. as stated in CAT5 (EIA
Note: CAT6 cables can normally only be terminated in sockets (female) and not in cable plugs.
CAT6 can thus only be used for longer cable draws terminating in wall outlets or patch panels.
Accessories (not supplied) |
|
Cat 5e Connection Cables (AWG24) |
|
EC | 10 03 12500 |
EC | 10 03 13101 |
EC | 10 03 13201 |
EC | 10 03 13501 |
EC | 10 03 14102 |
EC | 10 03 14202 |
EC | 10 03 14502 |
Technical specifications
General
Power consumption | max. 150W |
Mains voltage: | 100 - 240V, 50...60Hz |
Supply voltage for units | 48V/125W |
Temperature to guarantee specified performance
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
..........................
Weight | 1 kg |
Dimensions (W x H x D) | 100 (125) x 50 x 205 mm |
Dimensions in bracket are including the fixing bracket | |
Accessories supplied | Main cable |
Connectors |
|
2 pieces RJ45 |
Specifications are subject to change without notice.
14 | Manual 01 18 04450 |
|