NStor Technologies Disk Array Enclosure, CR8e Hot Swap Power Supplies, Power Switch, Door Lock

Page 17

Getting Started

If an error occurs, access the Operator Control Panel to determine the cause and locate the failed component. For more information, see Operator Control Panel on page 40. The fans are identified on the rear door panel using a placard for “FAN 1” and “FAN 2.” For more information on changing a cooling fan, see Replacing the Cooling Fans on page 60.

Hot Swap Power Supplies

CAUTION: Power supplies must be replaced by qualified service personnel only.

Up to three 150 watt hot swap power supplies are incorporated as part of a fault-tolerant design (N+1 power system). Each power supply unit (PSU) has current share circuitry which balances the load between the installed power supplies. In the event of a power supply failure, the load is transferred to the remaining power supplies without interruption to the CR8e’s normal operation.

If a failure occurs, the Power Supply Status LED will illuminate amber and an alarm will sound. The user can identify the failed component by accessing the OCP and viewing the “Hardware Status.” The PSU “DC Good” LED will not be illuminated on the failed power supply. For more information, see Replacing a Power Supply on page 58.

Power Switch

The power switch is located inside the locking front door and controls AC power to all of the power supplies. This positioning of the switch deters unauthorized users from powering down the CR8e provided the door is locked. The switch is recessed to prevent inadvertent activation during service activities.

The switch is labeled with a “I” for the ON condition and “O” for the OFF condition and is illuminated when the power is on for easy identification. Depending on the orientation of the subsystem (i.e., in the rack configuration) the “I” label will appear as a “” and should be interpreted as the ON condition.

Door Lock

The front door has an integral lock that also serves as a door handle. In addition, the door lock provides security to deter unauthorized access to the disk drives and SAF-TE card. Two keys are provided with the system.

To unlock the door, insert the key and turn it in a counterclockwise direction. To lock the door, turn the key in a clockwise direction.

Hot Swap Power Supplies

5

Image 17
Contents Page NStor Corporation, Inc Compliance Information Statement Regulatory InformationFCC Radio Frequency Interference Statement Power Cord Selection Contents Using the CR8e InstallationTroubleshooting MaintenanceIndex Glossary Technical InformationContents Welcome PrefaceDrive Support FeaturesRegistering Your Product Where to Find AnswersViii Getting Started Fuse CR8e Subsystem at a GlancePower Supply #1 Hot Swap Cooling Fans ComponentsHot Swap Disk Drives Door Lock Hot Swap Power SuppliesPower Switch Interface Card Power Cord Connector and FuseConfiguration Modules Operator Control Panel Controlling and MonitoringLEDs Power-On LEDStatus Indicator LEDs Activity LEDs Status LEDsSAF-TE Card Alarm SpeakerFault LEDs SAF-TE Card Setup InstallationGuidelines System RequirementsRack-Mount Subsystem Assembly Rack-Mount Subsystem Assembly Component Installation Drive Label Upper left bay, four drive slots Installing the Third Power Supply Cables Cabling ConfigurationGeneral Termination Dual-Bus Enclosure Ultra Wide Scsi ModeTOP Single-Bus Enclosure Installation Single Dual-Bus Enclosure Fast Wide Scsi ModeUltra Scsi Two Dual-Bus Enclosures Installation Bus Module installed Installation Two Single-Bus Enclosures Installation TOP Dual-Bus Enclosure with Two Single-Bus EnclosuresInstallation Other Configurations Power-On Self Test Using the CR8eNotifications and Error Conditions RAM Checksum Failure Firmware Error ConditionsScsi Bus Access Failure SAF-TE LED Matrix LED DescriptionsStartup Screens Operator Control PanelSubsystem Status Icon Power Supply Error ConditionsHardware Menu Main MenuConfiguration Info Component StatusPost Results Internal Temp Scsi ID Menu Options MenuSET Upper Slot IDS SET Safte ID Lower Reset Default IDS Reset Default IDs Selection Heat Threshold Safte Chain ID Change Passcode Unlock Options Common Enclosure Problems TroubleshootingCommon Scsi Bus Problems Scsi Bus Symptom Probable Cause Solution LED Status Reason Solution Common Problems and Interpreting the LED IndicationsReplacing a Disk Drive MaintenanceReplacing a Power Supply Replacing a Power Supply Replacing the Cooling Fans Replacing an I/O Interface Card Replacing a Fuse Replacing the CR8e Cabinet Maintenance Glossary Glossary RAID SAF-TE Technical Information SpecificationsCR8e ConnectorsSignal Name Pin Conductor Jumpers JP3 SCSI-to-SCSI IDs JP2 SCSI-to-SCSI ConfigurationJP4 Scsi ID Settings Pins 1 Pins 3 Drive Spinup Mode JP5 SCA Remote/Delay startJ15 FAN and J17 OEM FAN Index RAID SAF-TE Index

CR8e, Disk Array Enclosure specifications

NStor Technologies has long been recognized for its innovative storage solutions, and the CR8e Disk Array Enclosure is a prime example of this legacy. Designed to meet the growing demands of data storage in enterprise environments, the CR8e offers a robust and efficient platform for managing and securing critical data.

One of the standout features of the CR8e is its impressive capacity. Supporting up to eight 3.5-inch or 2.5-inch drive bays, it allows for flexibility in choosing the right drives, including SATA, SAS, and SSD options. This adaptability not only meets varying performance requirements but also ensures that organizations can tailor their storage solutions based on specific operational needs.

The CR8e is designed with redundancy in mind, featuring hot-swappable drive bays that enable users to replace drives without downtime, thus ensuring continuous operation. Additionally, its dual-redundant power supplies and cooling fans provide enhanced reliability. This feature is crucial for businesses that cannot afford interruptions, ensuring that their data remains secure and accessible at all times.

In terms of connectivity, the NStor CR8e supports multiple interface options, including both SAS and SATA, catering to different storage protocols and enhancing compatibility with existing systems. It is equipped with advanced RAID functionalities, supporting various RAID levels such as 0, 1, 5, and 6. This capability allows users to choose the most suitable data protection and performance strategy for their environment.

Management is made simple thanks to its user-friendly interface, which offers ease of configuration and monitoring. The enclosure also provides comprehensive diagnostic and reporting features, assisting administrators in maintaining optimal storage conditions and prolonging the lifespan of the equipment.

Furthermore, the CR8e is designed with scalability in mind. As data storage needs grow, organizations can easily expand their storage capacity by adding more enclosures. This feature allows businesses to future-proof their investments in storage technology.

NStor Technologies has incorporated cutting-edge technologies in the CR8e to ensure high-speed data transfer rates, reducing latency and enhancing overall system performance. The enclosure’s design emphasizes thermal efficiency, ensuring that the internal components are kept at optimal temperatures even during high-performance operations.

In summary, the NStor Technologies CR8e Disk Array Enclosure is a versatile and powerful solution for organizations seeking to enhance their data storage capabilities. With its robust features, excellent scalability, and emphasis on reliability, it stands out as an ideal choice for enterprises focused on safeguarding their data assets.