Waves L3-LL Interface Controls, Deleting Presets, A/B Comparison and Copying, Toggle Buttons

Page 21
Deleting Presets

L3-LL User Manual

Deleting Presets

You may delete User Presets and presets within a Setup File. Factory Presets and Setup Library files cannot be deleted or overwritten.

1.Hold the Command (Mac)/Control (PC) key down.

2.Click-and-hold the Load button to see the pop-up menu.

3.While still holding the Command/Control key, select the preset or setup to delete.

4.A confirmation box will appear, allowing you to cancel or ‘OK’ the deletion.

A/B Comparison and Copying

The Setup A/Setup B button may be clicked to compare two settings. If you load a preset in the Setup B position, this will not affect the preset loaded into the Setup A position, and vice-versa.

If you want to slightly modify the settings in Setup A, you can copy them to Setup B by clicking on the Copy to B button, then alter Setup A and compare with the original Setup B.

The name of the current setup will be shown in the title bar (on platforms which support it), and will switch as you change from Setup A to Setup B.

Note: an asterisk will be added to the preset name when a change is made to the preset -

4.3 Interface Controls

Controls can be in one of three states:

Not Selected where the control is not the target of any user entry

Selected where the control is the target of mouse control entry only

Selected and Active where the control is the target for both mouse and keyboard entry

Toggle Buttons

Toggle buttons display the state of a control, and allow switching between two or more states. Single- click to change the control’s state. Some toggle buttons have a text display which updates with the current setting, and others (bypass, solo, or monitoring toggles) illuminate when the control is active.

Some processors have link buttons between a pair of toggle buttons, allowing click-and-drag adjustment while retaining the offset between the controls.

21

Image 21
Contents L3-LLMultimaximizer Page TABLE OF CONTENTS 1.1 Welcome Chapter 1 - Introduction1.2 Product Overview Page The Peak Limiting Mixer 1.3 Concepts and TerminologyGain and Priority SeparationL3-LLRelease Behavior 1.4 ComponentsChapter 2 - Quickstart Guide Chapter 3 - Controls and Interface 3.1 Global Limiter SectionThreshold/Input Meter Threshold/Out Ceiling Link Out Ceiling/Output MeterAttenuation Meter Ultramaximizer ProfilesRange x0.1 to Ultramaximizer Release3.2 Graph Display and Controls Section Main Display Separation Band ControlsCrossover Xover Controls Per Band SoloGain Priority IndicatorsGain/Priority Link PriorityDefault ARC Master Release3.3 IDR Section IDR Active IndicatorQuantize DitherPreset Types 4.2 Preset HandlingChapter 4 - The WaveSystem 4.1 The WaveSystem ToolbarSaving Presets and Setups Loading Presets and SetupsPut into Preset Menu As… Save to New File…4.3 Interface Controls Deleting PresetsA/B Comparison and Copying Toggle ButtonsFaders Value Window ButtonsBand Markers Click-verticaldrag changes gainTAB Functions Multiple Selection of ControlsAppendix A - Controls List Dithering and Noise Shaping Appendix B - IDR In DepthIDR Dither Options Type1Type2 IDR Noise Shaping OptionsModerate Normal