Opticon OPT-6125 user manual Code 39 Settings, Options for Code

Page 24

Manual No. 25-ULGPMU01-01

Series OPT Handheld

CCD Scanner

 

Code 39 Settings (continued)

Code 39 is a variable length symbology with an optional check digit ("CD") and printable start/stop ("ST/SP") characters. The following characters are supported:

Numeric characters 0 to 9

Alpha characters capital A to Z

Special characters - $ / + % and SPACE

Start/stop character is *

The checksum is calculated as the sum modulo 43 of the numerical value of the data characters.

In full ASCII mode, all 128 ASCII characters are supported. This is done by combining one of the characters +, %, $ or / with one of the alpha characters (A to Z).

String format:

start

data (0 or

check

stop

char.

more characters)

digit

char.

Options for Code 39:

*Enable full ASCII conversion

*Enable Italian Pharmaceutical conversion

*Enable check digit

*Disable transmission of the check digit

*Enable transmission of start/stop

*Enable leading A for Italian Pharmaceutical

*Selection of the minimum number of data characters

Normal Code 39 - In this mode the decoded data characters are transmitted without further translation. Full ASCII Code 39 - In this mode the decoded data characters are translated to full ASCII Code 39.

Full ASCII Code 39 if possible - In this mode the decoded data characters are translated to full ASCII code 39. Invalid combinations are not translated and are transmitted as is.

Concatenation - If a Code 39 bar code contains a leading space, the data is stored into the reader's buffer without the leading space. As soon as a Code 39 bar code is read without a leading space, the data is appended to the reader's buffer and the entire buffer is transmitted and cleared for new data. In case a non Code 39 bar code bar is transmitted and the buffer is cleared. The buffer size is reader dependant.

Page 24

Image 24 Contents
User’s Manual Page Table of Contents General Information UnpackingFactory Technical Support Part II Installation and SetUp Installation Keyboard Wedge InterfaceReset All Defaults Keyboad Wedge Interface Computer Type Selection for Keyboard Wedge onlyIntercharacter Delay for Keyboard Wedge interface Installation RS232 Interface Reset All Defaults RS232RS-232C Communication Parameters Handshaking Protocol Baud RateData Bits / Stop Bits / Parity Installation USB Interface Reset All Defaults USB InterfaceStep-by-Step What If I Make a Mistake?Symbology Selection Start/EndSymbology Selection Symbology Additions Symbology Additions Setting the Number Characters to be Scanned UPC Settings Options for UPC-A and UPC-E bar codesUPC Settings String formatOptions for UPC-A Options for UPC-E EAN-13 and EAN-8 Settings EAN-13 and EAN-8 Settings Options for EANCode 39 Settings Minimum Digits Code 39 Settings Options for CodeCodabar Settings ABCD/ABCDOn Next Codabar Settings Start Data 1 or Check Stop Char More chars Digit Options for Codabar 2of5 Settings 2of5 Settings Options for Code 2of5MSI/Plessey Settings Options for MSI/PlesseyManual No -ULGPMU01-01 Series OPT Handheld CCD Scanner Code 128, EAN 128 Settings Manual No -ULGPMU01-01 Series OPT Handheld CCD Scanner Iata Settings CodeDescription Digits Options for IataTelepen Settings Options for TelepenCase Conversion Setting a Prefix or Suffix Prefix SettingsPrefix Settings Suffix Settings Suffix Settings Direct Input Keyboard Keys Direct Input Keyboard Keys Capslock Direct Input Characters Direct Input Characters Direct Input Characters ProgramMenu Direct Input Characters Direct Input Characters Direct Input Characters Direct Input Characters Direct Input Control Characters Direct Input Control Characters Direct Input Code ID/Length Read Mode Settings Trigger Settings Multiple Read Reset TimeQuiet Zone Settings Read Time Settings Redundant Decoding Settings Positive and Negative Bar CodesBuzzer Settings Buzzer Volume Buzzer Settings Diagnostics Good Read LED