Opticon OPT-6125 user manual Installation RS232 Interface, Reset All Defaults RS232

Page 8

Manual No. 25-ULGPMU01-01

Series OPT Handheld CCD Scanner

B.) Installation – RS232 Interface

The RS-232 scanner cable is terminated in with a DB9 female connector. An external power supply (+5V DC) may be necessary. There is a power supply jack on the RS-232 connector.

Installation is as follows:

1.Plug the scanner into an RS232 serial port (such as COM1) of the host PC. If external power is required, insert external power plug into the jack on the RS-232 connector.

2.Connect the power supply into an electrical outlet (110 V AC)

3.Turn on the power to the host computer. Make sure the communication parameters of the computer match those of the scanner. The default communications settings are: 9600 baud, 8 data bits, 1 stop bit, no parity, no handshaking

4.Be sure the PC is in a program (such as WordPad) that will accept input from the serial port.

Reset All Defaults – RS232

Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most applications, the scanner will work right out of the box without any need for additional programming. At any time you can return the scanner to the factory default settings by scanning the “Reset all Defaults” programming bar code below.

ZZ

Start

-[[-

Program Menu

 

 

 

U2

RS232

-V3-

 

 

 

ZZ

End

-[[-

Program Menu

 

 

 

Page 8

Image 8
Contents User’s Manual Page Table of Contents Factory Technical Support General InformationUnpacking Part II Installation and SetUp Installation Keyboard Wedge InterfaceReset All Defaults Keyboad Wedge Interface Computer Type Selection for Keyboard Wedge onlyIntercharacter Delay for Keyboard Wedge interface Installation RS232 Interface Reset All Defaults RS232RS-232C Communication Parameters Handshaking Protocol Baud RateData Bits / Stop Bits / Parity Installation USB Interface Reset All Defaults USB InterfaceStep-by-Step What If I Make a Mistake?Symbology Selection Start/EndSymbology Selection Symbology Additions Symbology Additions Setting the Number Characters to be Scanned UPC Settings Options for UPC-A and UPC-E bar codesUPC Settings String formatOptions for UPC-A Options for UPC-EEAN-13 and EAN-8 Settings EAN-13 and EAN-8 Settings Options for EANCode 39 Settings Minimum Digits Code 39 Settings Options for CodeCodabar Settings ABCD/ABCDOn Next Codabar Settings Start Data 1 or Check Stop Char More chars Digit Options for Codabar 2of5 Settings 2of5 Settings Options for Code 2of5MSI/Plessey Settings Options for MSI/PlesseyManual No -ULGPMU01-01 Series OPT Handheld CCD Scanner Code 128, EAN 128 Settings Manual No -ULGPMU01-01 Series OPT Handheld CCD Scanner Iata Settings CodeDescription Digits Options for IataTelepen Settings Options for TelepenCase Conversion Setting a Prefix or Suffix Prefix SettingsPrefix Settings Suffix Settings Suffix Settings Direct Input Keyboard Keys Direct Input Keyboard Keys Capslock Direct Input Characters Direct Input Characters Direct Input Characters ProgramMenu Direct Input Characters Direct Input Characters Direct Input Characters Direct Input Characters Direct Input Control Characters Direct Input Control Characters Direct Input Code ID/Length Read Mode Settings Trigger Settings Multiple Read Reset TimeQuiet Zone Settings Read Time Settings Redundant Decoding Settings Positive and Negative Bar CodesBuzzer Settings Buzzer Volume Buzzer Settings Diagnostics Good Read LED

OPT-6125 specifications

The Opticon OPT-6125 is an advanced handheld barcode scanner designed for various industrial applications, providing a blend of performance, durability, and user-friendliness. This versatile device is ideal for businesses looking to streamline their operations and enhance productivity through efficient inventory management and data capture.

One of the standout features of the OPT-6125 is its robust scanning capability. It employs a high-performance CMOS sensor that enables fast and accurate decoding of various barcode types, including 1D and 2D formats. This capability is crucial in environments where speed is essential, such as retail, warehouse management, and logistics.

The OPT-6125 is designed with ergonomics in mind, featuring a lightweight and compact form factor that ensures comfortable extended use for operators. The device is equipped with intuitive triggers, delivering a seamless scanning experience while minimizing user fatigue during prolonged work periods.

In terms of connectivity, the OPT-6125 supports multiple wireless technologies, including Bluetooth and USB. This flexibility allows for easy integration with smartphones, tablets, and various computing devices, facilitating real-time data transfer and increasing operational efficiency. Users can easily pair the scanner with their systems without the hassle of cables.

Durability is another key characteristic of the OPT-6125, boasting a robust housing that is built to withstand the rigors of a demanding work environment. It is rated IP54 for dust and water resistance, making it suitable for use in challenging conditions. Additionally, the device can endure drops from a height of up to 1.5 meters, ensuring longevity and reducing the need for frequent replacements.

The battery life of the OPT-6125 is also noteworthy, allowing for extensive usage on a single charge. This extended run time ensures that users can rely on the device throughout their working hours without interruptions. The scanner features an easy-to-read LED display that provides essential information regarding battery status and scanning performance.

In summary, the Opticon OPT-6125 stands out as a reliable and efficient data capture solution. Its combination of advanced scanning technology, ergonomic design, robust durability, and versatile connectivity options make it an ideal choice for businesses seeking to enhance their operational efficiency. With its impressive features and performance, the OPT-6125 is well-equipped to meet the demanding requirements of various industries.