Opticon NFT 2135, NFT 1125 manual Options for 2, Standard and Interleaved Format

Page 35

Manual No. 25-NFT1121-01

Series NFT-1121/2135 Mini CCD Fixed Position Scanners

8. Options for 2 of 5

 

Computer

 

Function

 

Bar Code

 

 

Command

 

/Description

 

Command

 

 

(Z7)

 

START/END

 

,Z7,

 

 

Programming Menu

 

 

 

 

 

 

 

 

 

 

 

G0

Do not calculate check digit

 

,G0,

B

 

 

 

 

 

 

 

 

 

G1

Calculate check digit

 

,G1,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G2

Transmit Check digit

 

,G2,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G3

Do not transmit check digit

 

,G3,

 

 

 

 

 

 

 

 

 

 

H6

Enable 2 characters

 

,H6,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H2

Disable 1 character Code 39 and

 

,H2,

 

 

Codabar (NW-7); Disable 2

 

 

 

 

characters 2 of 5

 

 

 

 

 

 

 

 

 

 

 

 

2 of 5 (Standard and Interleaved) Format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 to 44 data digits

 

CD

 

 

 

 

numeric only (0 to 9)

 

Check Digit

 

 

 

 

 

 

 

 

 

Opticon strongly recommends that the “Fixing the Number of Digits” feature on the next page be employed whenever 2 of 5 bar codes are used.

Page 29

Image 35
Contents Series NFT 1125/2135 User’s ManualThis page left intentionally blank for repagenation Contents This page left intentionally blank for repagenation Organization of this Manual This page left intentionally blank for repagenation Product Overview Quick Start-Up ProcedureSection Introduction and Getting Started Page Optical Specifications Section Technical SpecificationsPhysical Specifications Symbologies SupportedRS232 Communications Specifications Electrical SpecificationsEnvironmental Specifications Connector Pin-OutsPage Getting Optimum Performance Section Positioning the ScannerField-of-View Maximum Readable Bar Code Width LEDs Read Rate Test Measuring Scanner PerformanceTips for Insuring Highest Data Integrity Application NotesTips for Achieving High Throughput Tips for Verifying the Presence of a Bar Code Default Settings Section Configuring the ScannerProgramming Menus & Commands Page Modified and/or Customized Scanners Section Application Engineering SupportTechnical Assistance and Support Common Causes of Poor PerformancePage Appendix a Programming Menus & Commands Index Programming via Bar Codes Programming via Computer CommandsIntroduction Page Computer Function Bar Code Command Description Global Default & Scanner ConfigurationsSymbology Selection Symbology Selection Add/Activate Specific Bar Code SymbologiesAdd/Activate Specific Bar Code Symbologies Delete/Deactivate Specific Bar Code Symbologies Options for UPC Options for Code Options for Codabar NW-7 Options for Codabar NW-7 5 Standard and Interleaved Format Options for 2CPN Options for IataFixing the Number of Digits Creating a Prefix and/or Suffix Setting Prefixes Identifying the Symbology Setting Prefixes Identifying the Symbology Setting Suffixes Identifying the SymbologySetting Suffixes Identifying the Symbology Direct Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Control Characters Enable Number of Characters/Digits TransmittedSTART/END Enable Number of Characters/Digits TransmittedDisable Number of Characters/Digits Transmitted Communication Parameters Disable Number of Characters/Digits TransmittedCommunication Parameters Handshaking Buzzer Operation Buzzer Operation Positive & Negative Bar CodesSetting the Trigger Function Selecting the Read Mode Scanner Timeout Trigger Enabled Mode only Redundant Decoding STX?ETX for no read Transmitting Error Indications Trigger Enabled onlyPrint Quality Adjustments Page 1126/2126 Side View Appendix B Dimensional Drawings1127/2127 Front View Appendix C Optical Performance Charts