Lathem Configuring RS485 Communications DDC2/4-RS Series, Battery Usage DDC2 / DDC4 Series

Page 13

Page 7

Digital Display Wall Clock Guide

Configuring RS485 Communications - DDC2/4-RS Series

When multiple DDC2 (4)-RS Series Wall Clocks are installed as slave units to either the Lathem LTR4- 512 or LTR8-512 Master, LTR0 Mini-Master, Terminal Manager Software or the OMNI:CHRON Time Clock, the last clock on the line must have a shunt installed over both pins at position J2 (see figure 2, page 9). When shipped, the shunt is placed over only one pin of position J2 in an "open" setting. It is necessary to place the shunt over both pins of position J2 and create a "closed" setting for the last clock on the line.

DDC2-RS

Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and circuit board assembly out of the case. Place the lens aside and carefully flip the circuit board assembly over and lay it face down on a clean, smooth work surface. Locate position J2 on the left, upper side of the back of the circuit board assembly (see figure 2, page 9). Lift the shunt straight up off the single pin of position J2. Align the shunt to cover both pins of position J2 and press firmly into place. Slide the lens and circuit board assembly back into the case, replace the end cap, and secure with the four phillips head screws.

DDC4-RS

Remove the two phillips head screws from the left or the right end cap and remove. Slide the front panel assembly out of the case. Carefully flip the front panel assembly over and lay it face down on a clean, smooth work surface. Locate position J2 on the left, upper side of the back of the front panel. (See figure 2, page 9) Lift the shunt straight up off the single pin of position J2. Align the shunt to cover both pins of position J2 and press firmly into place. Slide the front panel display back into the case, replace the end cap and secure with the two phillips head screws.

Note: Only the LAST clock on the line needs position J2 "closed". Leave all other clocks "open".

Battery Usage - DDC2 / DDC4 Series

Depending on the secondary selection type, the 9-Volt alkaline battery (not included) performs different functions and may be required for proper operation.

DDC2/4-RS / DDC2/4-RS-24

When used as a secondary type clock the 9-Volt alkaline battery (not included) will retain the time that the power failure occurred, although the display will go blank. When power is restored, correction signals from the master clock will advance the wall clock to the proper time. When used as a secondary type clock in systems that do not provide a 12-Hour correction signal, the 9-Volt alkaline battery (not included) is required for proper operation. Without the 9-Volt alkaline battery (not included), the wall clock will reset to 12:00 AM after power resumes and will not receive the proper signal from the master clock to fully correct.

Image 13
Contents Installation & Users Guide Lathem Time Corporation Table of Contents Page Page Page Clock Operation IntroductionAbout this Manual DDC-TC Optional AccessoriesPage Setting the DIP Switches DDC2 / DDC4 Series Configuring the DDC Series Wall ClockDIP Switch Settings Battery Usage DDC2 / DDC4 Series Configuring RS485 Communications DDC2/4-RS SeriesDDC2/4-RS / DDC2/4-RS-24 Power Cord Installation DDC2/4-RS Battery Installation DDC2 / DDC4 SeriesSecondary Wiring Wiring Installation DDC2/4-RS SeriesRS485 Wiring DDC-TC WiringReplacing an Existing DDC4 Wall Clock Board Layout DiagramMounting to a Wall Mounting DDC2 / DDC4 SeriesMounting to a Single Gang Box DDC2 Double Mount Wall DDC2 Double Mount Wall DDC4 Double Mount Wall Double Mount Ceiling DDC2 Double Mount Ceiling DDC4 Double Mount Ceiling Time Formats Setting the TimeGrnd Appendix a DDC2-RS / 4-RS Secondary Clock Wiring DiagramsBLK Stand-Alone 115VACBRN / WHT BLU / WHT Wire Synchronous 115VACGrnd BLK Wire Synchronous 24VACAC RTN BLUYEL / WHT VIO / WHT BRN / WHT Wire minute Impulse 59th MinuteBLK YEL / WHT VIO / WHT BRN / WHT Wire Minute Impulse 59th Minute With 12 Hour CorrectionStandard Electric Synchronous BLK YEL Standard Electric AR-2A 2-Wire Dual VoltageStandard Electric AR-2 2-Wire Dual Voltage Synchronous Wired Simplex 59th Minute Dual Motor Simplex 45th Minute Dual Motor Edwards Dual Motor BLK YEL / WHT VIO / WHT BRN/ WHT Standard Electric AR-3 3-Wire Minute ImpulseNational Synchronous Wired Stromberg Synchronous Wired 56th Minute Cincinnati D1 CommonCincinnati D6, Edwards BLK VIO / WHT YEL / WHTVIO / WHT YEL / WHT Wire Pulse Alternating 24VDCElectronic Coded Grnd AC RTN BLK BLUStraight Frequency Wire Minute Impulse 58th Minute Wire Minute Impulse 44th Minute Wire Reverse Polarity Minute Impulse 59th Minute Appendix B DDC2-RS-24 / DDC4-RS-24 Wiring BLK BRN / WHT BLU / WHT DDC2-RS-24 / DDC4-RS-24 WiringRS485 Data Format Appendix C RS485 Wiring DiagramsGND OMCOmcii to DDC2-RS / 4-RS LTR0 to DDC2-RS / 4-RS BLK HLTR4 / 8-512 to DDC2-RS / 4-RS Terminal # Signal JP4 ConnectionWiring Appendix D DDC-TC Timer Control PanelTimer Control InstallationAs a Count Down Timer Operation As a Count Up TimerDWA-S Appendix E LTR-GPS Satellite Receiver / Clock SynchronizerPage Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clock DDC2 / DDC4 Appendix F SpecificationsLimited One-Year Limited Warranty Appendix G Warranty