Introduction

The Digital Display Series Wall Clocks are designed with 2-inch or 4-inch red LED displays that can be viewed from great distances; the 4-inch model as far away as 100 feet, the 2-inch model from as far away as 50 feet. The bright red display shows the hour and minutes and can be configured for a 12 or 24 hour format. By the setting of internal DIP switches, the DDC Series Wall Clocks can be configured to run as "stand-alone" or to replace many analog secondary clocks that may be hard to find or no longer available.

The DDC Series Wall Clocks can be synchronized from the Lathem LTR4-512 or LTR8-512 Master, LTR0 mini:master, Terminal Manager Software or the OMNI:CHRON Time Clock, using an RS485 correction signal.

The DDC Series Wall Clocks with the optional DDC-TC Timer Control Panel allow the DDC Series Wall Clocks to act as a count up or count down timer as well as displaying the normal time. The optional Timer Control Panel is required to use this feature.

The DDC Series Wall Clocks can be mounted directly to a wall, to a single gang outlet box or, with optional mounting kits, as double-faced units from the wall or ceiling.

During power failures, a 9-Volt alkaline battery (not supplied) can maintain the DDC Series Wall Clock's internal time keeping (although the display is blank during power failures).

Clock Operation

When the Digital Display Series Wall Clocks are set to operate as stand-alone or synchronous wired secondary clocks, the time base is derived from the AC power source. The frequency (50Hz or 60Hz) is automatically detected when power is applied. The clocks then initialize to 12:00AM and maintain time by counting the line frequency. Corrective clocks will begin synchronization routines. Accuracy is related directly to the accuracy of the line frequency. With the DDC-TC option, the Digital Display Series Wall Clocks can act as a count up or count down timer as well as running as a stand-alone or synchronous wired secondary clock.

When the Digital Display Series Wall Clocks are set to operate as impulse secondary clocks, the master clock controls time totally. Time will only advance when pulses are received from the master clock. Should the master clock lose power, the wall clocks would hold at the time that the last pulse was received until power to the master clock is restored and pulses continue. With the DDC-TC option, the Digital Display Series Wall Clocks can act as a count up or count down timer as well as running as an impulse secondary clock.

Image 7
Contents Installation & Users Guide Lathem Time Corporation Table of Contents Page Page Page Clock Operation IntroductionAbout this Manual DDC-TC Optional AccessoriesPage Setting the DIP Switches DDC2 / DDC4 Series Configuring the DDC Series Wall ClockDIP Switch Settings Battery Usage DDC2 / DDC4 Series Configuring RS485 Communications DDC2/4-RS SeriesDDC2/4-RS / DDC2/4-RS-24 Power Cord Installation DDC2/4-RS Battery Installation DDC2 / DDC4 SeriesDDC-TC Wiring Wiring Installation DDC2/4-RS SeriesSecondary Wiring RS485 WiringReplacing an Existing DDC4 Wall Clock Board Layout DiagramMounting to a Wall Mounting DDC2 / DDC4 SeriesMounting to a Single Gang Box DDC2 Double Mount Wall DDC2 Double Mount Wall DDC4 Double Mount Wall Double Mount Ceiling DDC2 Double Mount Ceiling DDC4 Double Mount Ceiling Time Formats Setting the TimeStand-Alone 115VAC Appendix a DDC2-RS / 4-RS Secondary Clock Wiring DiagramsGrnd BLKBRN / WHT BLU / WHT Wire Synchronous 115VACBLU Wire Synchronous 24VACGrnd BLK AC RTNYEL / WHT VIO / WHT BRN / WHT Wire minute Impulse 59th MinuteBLK YEL / WHT VIO / WHT BRN / WHT Wire Minute Impulse 59th Minute With 12 Hour CorrectionStandard Electric Synchronous BLK YEL Standard Electric AR-2A 2-Wire Dual VoltageStandard Electric AR-2 2-Wire Dual Voltage Synchronous Wired Simplex 59th Minute Dual Motor Simplex 45th Minute Dual Motor Edwards Dual Motor BLK YEL / WHT VIO / WHT BRN/ WHT Standard Electric AR-3 3-Wire Minute ImpulseNational Synchronous Wired Stromberg Synchronous Wired 56th Minute Cincinnati D1 CommonCincinnati D6, Edwards BLK VIO / WHT YEL / WHTVIO / WHT YEL / WHT Wire Pulse Alternating 24VDCElectronic Coded Grnd AC RTN BLK BLUStraight Frequency Wire Minute Impulse 58th Minute Wire Minute Impulse 44th Minute Wire Reverse Polarity Minute Impulse 59th Minute Appendix B DDC2-RS-24 / DDC4-RS-24 Wiring BLK BRN / WHT BLU / WHT DDC2-RS-24 / DDC4-RS-24 WiringRS485 Data Format Appendix C RS485 Wiring DiagramsGND OMCOmcii to DDC2-RS / 4-RS LTR0 to DDC2-RS / 4-RS BLK HLTR4 / 8-512 to DDC2-RS / 4-RS Terminal # Signal JP4 ConnectionWiring Appendix D DDC-TC Timer Control PanelTimer Control InstallationAs a Count Down Timer Operation As a Count Up TimerDWA-S Appendix E LTR-GPS Satellite Receiver / Clock SynchronizerPage Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clock DDC2 / DDC4 Appendix F SpecificationsLimited One-Year Limited Warranty Appendix G Warranty