Lathem ATDDC4 manual Mounting to a Wall, Mounting to a Single Gang Box, Double Mount Ceiling

Page 6

ATDDC4 Series Installation & User’s Guide

Mounting to a Wall

After deciding where to mount the clock, make two marks 12" apart and horizontal. Note: If mounting near a ceiling, make sure the holes are at least 2 1/4" away from the ceiling. Also, provide at least 16" of side clearance on one side in order to remove the front panel.

Installation Steps

1.Drill a 5/16" hole at each mark

2.Insert a wall anchor and tap it flush to the wall with the hammer.

3.Insert a screw into each wall anchor leaving 1/4" exposed.

4.Line up the two keyholes on the back of the case and slip over the two screws and tighten securely. ( The lower mounting holes can be marked at this point, the case removed, holes drilled and wall anchors installed if so desired)

Mounting to a Single Gang Box

Two mounting holes are located in the center of the case 2 1/4" apart for mounting to a single gang wall box. A 7/8" hole is located between the mounting holes that will accommodate conduit, if desired.

Note: If mounting near a ceiling, make sure the holes are at least 2- 1/4" away from the ceiling. Also, provide at least 16" of side clearance on one side in order to remove the front panel.

Line the two holes in the case up to the single gang box and insert proper screws for the single gang box and tighten securely.

ATDDC4 Series Installation & User’s Guide

Double Mount - Ceiling

Requires optional mounting kit (SAM0626)

Double-Mounting - Ceiling

Note: Make sure you have at least 16" of side clearance on one side in order to remove the front panel assembly.

1.Place the two clock enclosures back to back and secure by inserting a #10 screw through the four mounting holes using lock washers and nuts supplied with the mounting kit.

2.Note: If the ATDDC4 clocks will be mounted too near a wall on one side to secure the end caps, install the "wall side" end caps now.

3.Remove the center vent cap from the top of each ATDDC4 clock.

4.Line the two posts from the mounting plate up with the vent holes of the ATDDC4 clocks. Insert the chase nipples through the vent holes and secure to the mounting plate with a 15/16" wrench.

Page 4

Page 9

Image 6
Contents Model ATDDC4 Installation & User’s Guide ATX Clock Operation One Year Limited WarrantyIntroduction Front Panel Front Panel with optional 6 digit displayTime Formats Clock InstallationSpecifications Ordering OptionsBack Side of Circuit Board Mounting the EnclosureJumper J1 On = 12 Hour display Off = 24 Hour display Double Mount Ceiling Mounting to a WallMounting to a Single Gang Box Double-Mounting CeilingPower Cord Installation Double Mount Wall Attaching ConduitMaking the Connection Double-Mounting Wall