Lathem ATDDC4 Attaching Conduit, Making the Connection, Double Mount Wall, Double-Mounting Wall

Page 8

ATDDC4 Series Installation & User’s Guide

Attaching Conduit

The Electrical Supply can be brought into the ATDDC4 enclosure from any of the top three vent-hole positions, from the back, or from either side. Conduit access is not available from the bottom.

Note: Optional plastic end-panels may be ordered (left VIS1551-L), (right VIS1551-R) that have access holes pre-drilled to allow side access.

If Conduit access is through either of the optional plastic end- panels, Conduit should NOT be used to support the weight of the Clock. The Clock must be properly secured to a wall.

Remove the vent cap from the selected mounting hole (if not accessing through side panels). Attach the conduit with locking nut and extend the wires into the enclosure.

Making the Connection

1.Slide the circuit board with display part-way back into the case. Connect the two black wires from the circuit board to the power- wires from the power cord or conduit using wire nuts. Connect the Ground Wires from the circuit board and from the power source (usually green) to the green ground screw on the inside of he enclosure.

2.Slide the circuit board fully into place, then slide the front lens into place. Note: the inside of the lens has a paper backing which should not be removed. The end with wider paper should go to the right. Replace the end caps and secure with the two Phillips head screws.

3.When the clock is energized, it will set itself, upon receiving the AirTime radio signal.

ATDDC4 Series Installation & User’s Guide

Double Mount – Wall

The ATDDC4 SERIES requires optional mounting kit (SAM0625)

Tools required for mounting the clock:

Flat blade screwdriver

Phillips head screwdriver

15/16" open end wrench

The double wall mount plate attaches to a double or single gang box installed securely in the wall. Required wiring should be available through the gang box at time of installation.

Installation Steps

1.Remove the two chase nipples from the mounting plate posts.

2.Secure the mounting plate securely to the gang box with the proper screws. (not supplied)

Note: The long dimension of the mounting plate must be perpendicular to the ground to assure proper alignment of wall clocks.

See remaining Wall or Ceiling mount instructions below

Double-Mounting - Wall

1.Place the two clock enclosures back to back and secure by inserting a #10 screw through the four mounting holes using lock washers and nuts supplied with the mounting kit.

2.Attach the modified end cap to the clock’s end to be attached to the wall mount plate using the original end cap screws.

3.Align the holes of end cap support plate with the holes in the modified end cap and secure with 4 #6 Phillips head screws (supplied).

4.Line the two posts from the mounting plate up with the two holes of the modified end cap. Insert the chase nipples through the holes of the modified end cap and secure to the mounting plate with a 15/16" wrench.

Page 6

Page 7

Image 8
Contents Model ATDDC4 Installation & User’s Guide ATX One Year Limited Warranty IntroductionClock Operation Front Panel Front Panel with optional 6 digit displayClock Installation SpecificationsTime Formats Ordering OptionsJumper J1 On = 12 Hour display Off = 24 Hour display Back Side of Circuit BoardMounting the Enclosure Mounting to a Wall Mounting to a Single Gang BoxDouble Mount Ceiling Double-Mounting CeilingPower Cord Installation Attaching Conduit Making the ConnectionDouble Mount Wall Double-Mounting Wall