La Crosse Technology WS-7013TWC quick start

Page 16

Solution: Each temperature sensor is manufactured to be accurate to within 1 degree plus or minus and under normal conditions; so two sensors could be as much as 2 degrees different. However, the difference can be exaggerated further because the sensors are designed for different working environments. The indoor sensor is less responsive to ambient air currents because of the shielding effect of the display's case. In addition, the case can act as a heat sink to absorb and store heat from external sources (i.e. handling of the case or radiant heat). In addition, the much greater range of the outdoor temperature sensor requires a different calibration curve than the indoor range. Error is usually greater at the extreme ends of a range, making it harder to compare different ranges with different curves. Under non-laboratory conditions, it is difficult to compensate for the above factors and obtain an accurate comparison.

13

Image 16
Contents Quick Start for your WS-7013U WS-7013U Wireless 433 MHz Temperature Station Table of Contents Inventory of Contents Quick Setup Detailed Setup Guide Battery Installation Outdoor II. Time Setting the Time IV. Features Minimum and Maximum Temperatures Adding Additional Remote Control Senders Optional Resetting the Minimum and Maximum TemperaturesPage Page Mounting Remote Control Sender Temperature StationPage Troubleshooting Page Maintenance and Care Instructions Specifications Measuring TemperaturesWarranty Information Page Page Support@lacrossetechnology.com FCC Disclaimer