La Crosse Technology WT-5432 Maintenance and Care, Troubleshooting, Problem, Solution

Page 13

3.Adhere the tape to the designated area on the back of the mounting bracket.

4.Remove the protective strip from the other side of the tape.

5.Position the remote temperature sensor in the desired location, ensuring that the projection alarm can receive the signal.

V.Maintenance and Care

A.Extreme temperatures, vibrations, and shock should be avoided to prevent damage to the units.

B.Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents—they may mark and damage the displays and casings.

C.Do not submerge in water.

D.Immediately remove all low powered batteries to avoid leakage and damage.

E.Replace with new batteries only, and of recommended size.

F.Opening the casings invalidates the warranty. Do not try to repair the units. Contact La Crosse Technology for Repairs.

TROUBLESHOOTING

Problem:

The projection is faint

Solution:

1)

Change intensity setting

 

2)

Use AC adapter

 

3)

Darken surroundings

 

4)

Use fresh batteries (if AC is not used)

Problem:

The LCD is faint.

Solution:

1)

Replace the batteries.

Problem:

“OFL” appears in the indoor temperature LCD.

Solution:

1)

Move unit to an area with warmer or cooler surrounding

 

temperature. Current surrounding temperatures are outside

 

measuring range.

Problem:

No reception of WWVB signal.

Solution:

1)

It may help reception to face the front of the projection alarm

 

 

in the general direction of Ft. Collins, Colorado.

 

2)

Wait overnight for signal.

 

3)

Be sure the projection alarm is at least 6 feet from any

 

 

electrical devices, i.e. TV sets, computers, or other radio

 

 

controlled clocks.

 

4)

Remove batteries for five minutes, reinsert and leave the unit

 

 

alone overnight without pressing buttons.

 

5)

Try leaving batteries in unit, but unplug the AC adapter

 

 

overnight. The first signal is most difficult to receive clearly,

 

 

and even a slight interference may cause failure of WWVB

 

 

13

Image 13
Contents WT-5432 433 MHz Radio Controlled Projection Alarm Table of Contents Quick SET-UP Guide Inventory of ContentsRemote Temperature Sensor Battery InstallationProjection Alarm Detailed SET-UP GuideTime Zone Setting II. Program ModeProgramming Sequence Function ButtonsAdjustable Snooze Time DST Daylight Saving Time SettingTime Setting 12/24-Hour Setting/ Selecting F or C Date SettingIII. Features and Operations Radio-Controlled Time and Date Weather Icons Forecast IconRemote Temperature Indoor TemperatureEL Backlight Setting the Alarm Time AlarmActivating/Deactivating the Alarm Turning the Alarm Off While SoundingIV. Mounting the Remote Temperature Sensor Changing the Display Mode Day, Seconds and TemperatureMounting with Screws Mounting with Adhesive TapeTroubleshooting Maintenance and CareProblem SolutionTemperature SpecificationsPower source Dimensions L x W x HWarranty Information FCC ID OMO-01RX receiver OMO-01TX transmitter