PSC QS2500 manual Symbology Settings, Upc-A

Page 31

Symbology Settings

UPC-A

Read: Format:

Leading Zero

Data Digits (11 Digits) Check Digit

Checksum Transmission: With this option enabled, the QS2500 will trans- mit the checksum.

Truncate Leading/Ending: The leading or ending digits of bar code data characters can be truncated. The QS2500 will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

Code ID Setting: The code ID represents the bar code type. It is affixed to the beginning or end of the transmitted data if the feature is selected. If you want your application to transmit the code ID, you must set the code ID transmission option to 01 first. See page 26.

Insertion Group Selection: The QS2500 offers one or two insertion groups for a symbology. Set one or two digits to indicate which insertion group you desire. See pages 2224for information about insertion groups.

Examples:

Group 2 set 02 or 20

 

Group 1 and 4 set 14 or 41

Supplement Digits: Are the supplemental 2 or 5 characters for WPC code. Format:

Leading Zero Data Digits (11 Digits) Check Digit

Supplemental Digits

(2 or 5)

Truncate Leading Zero: The 13th digit (always a zero) can be truncated.

Examples: Bar code: “0462531256712”

Output: “462531256712”

Expanding to EAN13: Expands a UPC bar code by adding a leading zero and sending it to the host in EAN13 format.

Product Reference Guide

27

Image 31
Contents Page Patents Installation Appendix E Alphanumeric Characters RS-232 InstallationKeyboard Wedge Wand EmulationUSB Scan the alphanumeric characters located in Appendix E Programming the QS2500Interfaces Resetting the QS2500Option Bar Code Alphanumeric QS2500 Intercharacter Delay 99 10 msec Keyboard Wedge Default Baud Rate None Parity Odd Even RS-232 Advanced Features Response Delay IBM Interface 46XX/USB IBM 46xx Code 39 Conversion IBM OptionsIBM Host Commands Standby Duration Scanning ModeSame Bar Code Delay Time ScanningMultifield Scan Double ConfirmDisable Multifield Scan Enable Option Alphanumeric Entry Beep/Tone/LED Settings Beep & LED after decode Label Editing includes Prefix/Suffix Option Bar Code Option Bar Code Alphanumeric Insert Data Group Disable ID Transmission Enable UPC-A Symbology SettingsUCC/EAN UPC-E Truncate Ending FfH Ascii code EAN-13 Disable Checksum Transmission Enable EAN-8 Ascii Code Use Global Min Minimum Code Length Interleaved 2 Use Global Min Code Length Industrial 2 Matrix 2 Ff hexB Codabar ABCD/ABCD Data Checksum UCC/EAN-128 Disable Append Enable Ff hex Ascii Enable two digits Data Digits Variable Checksum1 Optional MSI/Plessey Mini UK/Plessey Disable Enable Checksum Verification Checksum Transmission Telepen Standard 2 Disable Enable Code 16K Option Bar Code Alphanumeric Italian PharmaCode RSS Expanded RSS Limited RSS-14 Checksum Code Code Type Appendix Default SettingsEAN-8 Appendix B Bar Code Samples1 2 + B 2 3 4 5 B c d 7 8 9 0 B c d Italian PharmaCode RSS Expanded RSS Limited RSS-14 Appendix C Ascii Codes Example Ascii a = QS2500 Start Program Standard Parameter Setting List Appendix D Parameter Setting ListAppendix E Alphanumeric Characters Declaration of Conformity PSC Inc