PSC QS2500 manual Code

Page 39

Code 39

Read: Format:

Start “*”

Data Digits (Variable) Checksum (Optional)

End “*”

Checksum Verification: The checksum is optional and presented as the sum mod 43 of the numerical value of the data digits.

Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum.

Maximum/Minimum Code Length: Each symbology has own maximum and minimum code length, which can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with lengths below the minimum or above the maximum will be rejected. If the maxi- mum and minimum code lengths for a specific symbology are both set to zero, the global minimum and maximum code length settings are in effect.

 

Make sure that the minimum length setting is not greater than the maxi-

 

mum length setting; otherwise, all the labels of the symbology will be

 

unreadable. You can set the same value for both minimum and maximum

NOTE

length to force decoding of only bar codes of a certain length.

 

Truncate Leading/Ending: Same as UPC-A. See page 27.

Code ID Setting: Same as UPC-A. See page 27.

Insertion Group Selection: Same as UPC-A. See page 27.

Format: The Full ASCII Code 39, an enhanced set of Code 39, uses a total of 128 characters to represent Full ASCII code. Each Full ASCII Code 39 character is a combination of one of the characters +,%, $ and / with an uppercase alphabetical character (A to Z).

Product Reference Guide

35

Image 39
Contents Page Patents Installation Appendix E Alphanumeric Characters RS-232 InstallationKeyboard Wedge Wand EmulationUSB Scan the alphanumeric characters located in Appendix E Programming the QS2500Interfaces Resetting the QS2500Option Bar Code Alphanumeric QS2500 Intercharacter Delay 99 10 msec Keyboard Wedge Default Baud Rate None Parity Odd Even RS-232 Advanced Features Response Delay IBM Interface 46XX/USB IBM 46xx Code 39 Conversion IBM OptionsIBM Host Commands Standby Duration Scanning ModeSame Bar Code Delay Time ScanningMultifield Scan Double ConfirmDisable Multifield Scan Enable Option Alphanumeric Entry Beep/Tone/LED Settings Beep & LED after decode Label Editing includes Prefix/Suffix Option Bar Code Option Bar Code Alphanumeric Insert Data Group Disable ID Transmission Enable UPC-A Symbology SettingsUCC/EAN UPC-E Truncate Ending FfH Ascii code EAN-13 Disable Checksum Transmission Enable EAN-8 Ascii Code Use Global Min Minimum Code Length Interleaved 2 Use Global Min Code Length Industrial 2 Matrix 2 Ff hexB Codabar ABCD/ABCD Data Checksum UCC/EAN-128 Disable Append Enable Ff hex Ascii Enable two digits Data Digits Variable Checksum1 Optional MSI/Plessey Mini UK/Plessey Disable Enable Checksum Verification Checksum Transmission Telepen Standard 2 Disable Enable Code 16K Option Bar Code Alphanumeric Italian PharmaCode RSS Expanded RSS Limited RSS-14 Checksum Code Code Type Appendix Default SettingsEAN-8 Appendix B Bar Code Samples1 2 + B 2 3 4 5 B c d 7 8 9 0 B c d Italian PharmaCode RSS Expanded RSS Limited RSS-14 Appendix C Ascii Codes Example Ascii a = QS2500 Start Program Standard Parameter Setting List Appendix D Parameter Setting ListAppendix E Alphanumeric Characters Declaration of Conformity PSC Inc