13.3 Biamp System Parameters

Parameter

Unit/Name

Low Section

High Section

 

 

 

 

Gain

(dB)

0

-1.0

Delay

(ms)

0.167

0

Polarity

 

Positive

Positive

 

 

 

 

HPF Ä

Freq (Hz)

42.5

1680

 

Slope (dB/oct)

24

24

 

Filter Shape

Butterworth

Linkwitz Riley

 

 

 

 

LPF

Freq (Hz)

1470

Thru

 

Slope (dB/oct)

24

NA

 

Filter Shape

Linkwitz Riley

NA

 

 

 

 

PEQ 1 Ä

Freq (Hz)

62.5

2720

 

Level (dB)

+7

-4

 

Type

Parametric

Parametric

 

Q / Bandwidth

2.0 / 0.5000

2.1 / 0.4719

 

 

 

 

PEQ 2

Freq (Hz)

454

10700

 

Level (dB)

-3

+5

 

Type

Parametric

Parametric

 

Q / Bandwidth

1.7 / 0.5946

1.9 / 0.5297

 

 

 

 

PEQ 3

Freq (Hz)

642

15100

 

Level (dB)

-2

+3

 

Type

Parametric

2.4 / 0.4204

 

Q / Bandwidth

4.0 / 0.2500

NA

 

 

 

 

PEQ 4

Freq (Hz)

1010

NA

 

Level (dB)

+6

NA

 

Type

Parametric

NA

 

Q / Bandwidth

4.0 / 0.2500

NA

 

 

 

 

PEQ 5

Freq (Hz)

NA

NA

 

Level (dB)

NA

NA

 

Type

NA

NA

 

Q / Bandwidth

NA

NA

 

 

 

 

ÄNote : When using the V12HP with subs, set HPF on LF section @ 80 – 110Hz (24dB/oct LR) and omit PEQ1 (on LF only)

PEQ 1 (on LF only) may also be omitted when using the V12HP as a floor monitor.

Image 19
Contents Page Page Contents Introduction Connectors/CablingUnpacking 11.0 17.0100 17.0 35.0 11.0 22.0 14.0 Polarity Checking Crossovers Amplification & Power HandlingEqualisation Arraying V12HPDimensions Page 99dB anechoic 102dB half space Technical SpecificationsRigging & Suspension General Safety Advice Secur ET VMY Yoke Bracket Description Number on Fig Secur ET VEB Eyebolt Important It is imperative for safety reasons thatCorrect method is shown in figure Quantity Secur ET VTH Pole MountSecur ET VCS Ceiling Saddle Secur ET VPC Pole ClampMust be adhered to for optimum performance Polarity DelayPassive System Parameters optional Parameter Unit/Name Gain167 ML5 4TF WarrantyEMCV12HP Declaration of ConformityGH August