Tannoy V12HP user manual 100 17.0 35.0 11.0 22.0 14.0 Polarity Checking

Page 5

Cable choice consists mainly of selecting the correct cross sectional area in relation to the cable length and the load impedance. A small cross sectional area would increase the cables series resistance, inducing power loss and response variations (damping factor).

Connectors should be wired with a minimum of 2.5 sq. mm (12 gauge) cable. This will be perfectly satisfactory under normal conditions. In the case of very long cable runs the wire size should exceed this, refer to the following table for guidance:-

CABLE RUN (m)

C.S.A. OF EACH

CABLE

% POWER LOSS

% POWER LOSS

 

CONDUCTOR (mm)

RESISTANCE Ω

INTO 8Ω LOAD

INTO 4Ω LOAD

10

2.5

0.14

1.7

3.5

 

4.0

0.09

1.1

2.2

 

6.0

0.06

0.73

1.5

25

2.5

0.35

4.3

8.6

 

4.0

0.22

2.7

5.4

 

6.0

0.14

1.8

3.6

50

2.5

0.69

8.6

17.0

 

4.0

0.43

5.4

11.0

 

6.0

0.29

3.6

7.2

100

2.5

1.38

17.0

35.0

 

4.0

0.86

11.0

22.0

 

6.0

0.58

7.2

14.0

4. Polarity Checking

It is most important to check the polarity of the wiring before the speaker system is flown. A simple method of doing this without a pulse based polarity checker for LF units is as follows: Connect two wires to the +ve and -ve terminals of a PP3 battery. Apply the wire which is connected to the +ve terminal of the battery to the speaker cable leg which you believe to be connected to pin 1+ of the speaker connector and likewise the -ve leg of the battery to pin 1-.

If you have wired it correctly the LF drive unit will move forward, indicating the wiring is correct. All that remains now is to connect the +ve speaker lead to the +ve terminal on the amplifier and the - ve lead to the -ve terminal on the amplifier. If however the LF driver moves backwards, the input connections need to be inverted.

If problems are encountered, inspect the cable wiring in the first instance. It should also be noted that different amplifier manufacturers utilise different pin configurations and polarity conventions, if you are using amplifiers from more than one manufacturer, check the polarity at the amplifiers as well as the loudspeakers.

Image 5
Contents Page Page Contents Unpacking Connectors/CablingIntroduction 100 17.0 35.0 11.0 22.0 14.0 Polarity Checking 17.011.0 Equalisation Amplification & Power HandlingCrossovers Arraying V12HPDimensions Page 99dB anechoic 102dB half space Technical SpecificationsRigging & Suspension General Safety Advice Secur ET VMY Yoke Bracket Description Number on Fig Correct method is shown in figure Important It is imperative for safety reasons thatSecur ET VEB Eyebolt Secur ET VCS Ceiling Saddle Secur ET VTH Pole MountSecur ET VPC Pole Clamp QuantityMust be adhered to for optimum performance Passive System Parameters optional DelayParameter Unit/Name Gain Polarity167 ML5 4TF WarrantyEMCV12HP Declaration of ConformityGH August