ADDITIONAL TEST / DIAGNOSTICS COMMANDS...

%L RECEIVED SIGNAL LEVEL

Returns a value (-dBm) which indicates the received signal level at modem DATA PUMP interface. This value is determined by the loss/gain of modem Telco Interface circuit ±dB at the Tip/Ring input to the modem. Typical value should be -25dBm to -35dBm for most Telco connections.

%Q RECEIVED LINE SIGNAL QUALITY

Reports the line signal quality at the modem DATA PUMP interface. This signal is also dependent on the DAA circuit (Telco Interface). Returns the higher order byte of the EQM (Eye Quality Monitor is the filter squared magnitude of the error vector). Typical value should be below 10. The lower the number, the better the performance from the modem.

ERROR response if NO connection to remote modem.

In &T1, modem %Q will be 0.

S86 CONNECTION FAILURE CAUSE

S86 can help determine the cause of a connection failure. When the modem issues a NO CARRIER result code, a value is written to this register. To read this register, following the connection failure, issue ATS86? <CR>. The modem will report one of the following values...

MIU Installation, Operation & Diagnostics Edition: March 30, 1998

Page 27

Image 29
Contents Installation, Operation & Diagnostics Telenetics Corporation Table of Contents USA StandardsProduct Overview MIU Installation, Operation & Diagnostics Edition March 30 MIU28.8 General Product SpecificationsMode Description Power Consumption Power On Power ModesPower Down SleepMIU2.4 MIU9.6 MIU14.4 MIU28.8 Modem SpecificationsPower Connections Serial Data Port PIN-OUTS DIP Switch Settings Not Applicable Auto Dial Feature LED IndicatorAuto Reset Feature Outline Drawing & Mounting Modem Configuration Telephone Numbers &Z0= Factory Configuration ~ MIU2.4 Active ProfileStored Profile Telephone Numbers Factory Configuration ~ MIU9.6 Active ProfileFactory Configuration ~ MIU14.4 Active Profile Factory Configuration ~ MIU28.8 Active Profile Diagnostics Result Code Description T0 Terminate Test in ProgressT1 Initiate Local Analog Loopback See Figure Grant Remote Digital Loopback RDL Requests No FunctionPerform Local Digital Loopback See Figure T6 Initiate Remote Digital Loopback See Figure T5 Deny RDL RequestsResult Codes Description T7 Initiate RDL with Local Self Test See FigureT6, &T7, or if on-line T8 Local Loopback with Self Test See FigureMIU Installation, Operation & Diagnostics Edition March 30 MIU Installation, Operation & Diagnostics Edition March 30 MIU Installation, Operation & Diagnostics Edition March 30 S86 Connection Failure Cause Received Line Signal QualityMIU Installation, Operation & Diagnostics Edition March 30 MIU Installation, Operation & Diagnostics Edition March 30