Telenetics manual Modem Specifications, MIU2.4 MIU9.6 MIU14.4 MIU28.8

Page 9

5.MODEM SPECIFICATIONS

 

MIU2.4

MIU9.6

MIU14.4

MIU28.8

Standards

V.22bis

V.22bis

V.32bis

V.34

 

V.22

V.22

V.32

V.32bis

 

Bell212A

Bell212A

V.22bis

V.32

 

Bell 103

Bell 103

V.22

V.22bis

 

 

 

Bell212A

V.22

 

 

 

Bell 103

Bell212A

 

 

 

 

Bell 103

 

 

 

 

 

Modem Line

2400bps

2400bps

14400bps

28800bps

Speed

1200bps

1200bps

9600bps

19200bps

(Asynch)

300bps

300bps

4800bps

14400bps

 

 

 

2400bps

9600bps

 

 

 

1200bps

4800bps

 

 

 

300bps

2400bps

 

 

 

 

1200bps

 

 

 

 

300bps

 

 

 

 

 

DTE Rates

-

19200bps

57600bps

115200bps

above Modem

 

9600bps

38400bps

57600bps

Line Speeds

 

4800bps

19200bps

38400bps

 

 

 

 

19200bps

 

 

 

 

 

Error

-

MNP 2,3,5

MNP 2,3,5

MNP 2,3,5

Correction &

 

& 10

& 10

& 10

Data

 

V.42

V.42

V.42

Compression

 

V.42bis

V.42bis

V.42bis

 

 

 

 

 

MIU Installation, Operation & Diagnostics Edition: March 30, 1998

Page 7

Image 9
Contents Installation, Operation & Diagnostics Telenetics Corporation Table of Contents USA StandardsProduct Overview MIU Installation, Operation & Diagnostics Edition March 30 MIU28.8 General Product SpecificationsMode Description Power Consumption Power On Power ModesPower Down SleepMIU2.4 MIU9.6 MIU14.4 MIU28.8 Modem SpecificationsPower Connections Serial Data Port PIN-OUTS DIP Switch Settings Not Applicable LED Indicator Auto Reset FeatureAuto Dial Feature Outline Drawing & Mounting Modem Configuration Factory Configuration ~ MIU2.4 Active Profile Stored ProfileTelephone Numbers &Z0= Telephone Numbers Factory Configuration ~ MIU9.6 Active ProfileFactory Configuration ~ MIU14.4 Active Profile Factory Configuration ~ MIU28.8 Active Profile Diagnostics T0 Terminate Test in Progress T1 Initiate Local Analog Loopback See FigureResult Code Description No Function Perform Local Digital Loopback See FigureGrant Remote Digital Loopback RDL Requests T6 Initiate Remote Digital Loopback See Figure T5 Deny RDL RequestsResult Codes Description T7 Initiate RDL with Local Self Test See FigureT6, &T7, or if on-line T8 Local Loopback with Self Test See FigureMIU Installation, Operation & Diagnostics Edition March 30 MIU Installation, Operation & Diagnostics Edition March 30 MIU Installation, Operation & Diagnostics Edition March 30 S86 Connection Failure Cause Received Line Signal QualityMIU Installation, Operation & Diagnostics Edition March 30 MIU Installation, Operation & Diagnostics Edition March 30