12.0 TECHNICAL SPECIFICATIONS AND DRAWINGS
iwSA 500 SUBWOOFER AMPLIFIER
PERFORMANCE |
|
| |
Maximum Output Power (1) (2) | 500 Watts Continuous into 4 Ω |
| |
|
| 250 Watts Continuous into 8 Ω |
|
|
|
|
|
Minimum Nominal | 4 Ω |
| |
Load Impedance |
|
| |
|
|
|
|
Distortion | <1% @ Maximum Rated Output |
| |
|
|
|
|
Minimum Frequency Bandwidth | 20Hz - 500Hz (no filters or EQ) |
| |
|
|
|
|
Input Impedance | >20 kΩ |
| |
|
|
|
|
Current Draw at 4 Ω | 5 Amps |
| |
|
|
|
|
FRONT PANEL |
|
| |
Level Control | Adjusts Input Signal Level |
| |
|
|
|
|
Crossover Frequency Adjustment | 50Hz - 150Hz |
| |
|
|
|
|
Phase Control | 0° - 180° Continuously Variable |
| |
|
|
|
|
Crossover/Bypass Switch | Engages or Disengages Low Pass Filter |
| |
|
|
|
|
On/Auto Switch | On Continuous / Sleep Mode |
| |
|
|
|
|
Power On Indicator | Blue LED |
| |
|
|
|
|
REAR PANEL |
|
| |
Input Connectors | 2 x RCA |
| |
|
|
|
|
Link Connectors | 2 x RCA |
| |
|
|
|
|
Output Connectors | 4 x Gold Plated Binding Postings |
| |
|
|
|
|
Mains Voltage Connector | 120 Volt IEC - 2 Conductor |
| |
|
|
|
|
Mains Voltage Fuse Holder | T5AL, 250 Volt |
| |
|
|
|
|
REAR PANEL SWITCHES |
|
| |
Power Switch |
|
| |
|
|
|
|
Limiter Function | Switchable 1 Sub or 2 Sub (See Page 9.) |
| |
|
|
|
|
DIMENSIONS |
|
| |
incl. Feet & Rack Ears |
|
| |
Net Dimensions (HxWxD) | 99 x 483 x 372 (37/8 x 19 x 145/8) |
| |
|
|
|
|
Shipping Dimensions (HxWxD) | 208 x 538 x 445 (83/16 x 213/16 x 171/2) |
| |
|
|
|
|
WEIGHT |
|
| |
Net Weight (each) - kgs (lbs) | 6.8 (15) |
| |
|
|
| |
Shipping Weight (each) - kgs (lbs) 8.6 (19) |
| ||
|
|
|
|
APPROVALS | NOTES |
| |
CSA C/US & FCC | (1) Thermal protection may occur at high continuous power. |
| |
|
| (2) Depending on configuration, output power may be lower due to limiting circuit. |
|
427
(167/8)
|
| LEVEL | CROSSOVER |
| PHASE |
|
| + |
|
| CAUTION |
|
|
|
| FREQUENCY |
|
|
|
|
|
|
| OFF | ON |
90 |
|
|
|
|
|
|
| 1 SUB |
| |||
|
|
| BY PASS | ON | POWER |
|
|
| ATTENTION |
| ||
|
|
|
|
|
|
|
|
| 5A 120V~60HZ | |||
|
|
|
|
|
|
|
|
| CAUTION: |
| ||
(31/ |
| ) |
|
|
|
|
|
|
|
| FOR CONTINUED PROTECTION |
|
2 |
|
| CROSSOVER | AUTO |
|
|
|
| AGAINST RISK OF FIRE, REPLACE |
| ||
|
|
|
| OUTPUT 1 | OUTPUT 2 | LINE IN | LINE OUT | ONLY WITH SAME TYPE FUSE AND RATING. |
| |||
|
|
|
|
|
|
|
| 2 SUBS |
| ATTENTION: |
| |
|
| 50 | 150 | 0 | 180 |
|
|
| LIMITER |
| UTILISER UN FUSIBLE DE RECHANGE |
|
|
|
|
|
|
|
| + | + | FUNCTION |
| DE MEME TYPE ET CALIBRE. |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| T5AL 250V |
iwSA 500
9