Silicon Image SSD-D16G(I)-3600 manual Sector Number Register, Read/Write

Page 28

ATA REGISTERS

SSD-DXXX(I)-3600 DATA SHEET

SECTOR NUMBER REGISTER

The Sector Number register is set by the host to specify the starting sector number associated with the next ATA command to be executed. Following a qualified ATA command sequence, the device sets the register value to the last sector read or written as a result of the previous AT command.

When Logical Block Addressing (LBA) mode is implemented and the host issues a command, the contents of the register describe the Logical Block Number bits A[7:0]. Following an ATA command, the device loads the register with the LBA block number resulting from the last ATA command.

Table 20: Sector Number Register

Operation

D7

D6

D5

D4

D3

D2

 

D1

D0

Read/Write

 

 

Sector Number (CHS Addressing)

 

 

 

 

 

Logical Block Number bits A07-A00 (LBA Addressing)

 

 

 

 

 

 

 

 

 

 

Default Value

0

0

0

0

0

0

 

0

1

 

 

 

 

 

 

 

 

 

 

SILICONSYSTEMS PROPRIETARY

This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.

All unauthorized use and/or reproduction is prohibited.

3600D-04DSR

PAGE 19

FEBRUARY 2, 2009

Image 28
Contents Features OverviewUpdated Revision HistoryDocument No Release Date Changes AddedTable of Contents SSD-DXXXI-3600 Data Sheet Sales and Support Part Numbering Related DocumentationList of Figures List of Tables Idle Immediate 95h, E1h SSD-DXXXI-3600 Data Sheet Physical Specifications Physical DimensionsPin Locations System Power Requirements Product SpecificationsSystem Performance Reliability SiliconDrive Part# Capacity Service Life GB Written per DayOperational Life Span Environmental Specifications Product Capacity SpecificationsProduct Capacity Number Bytes Sectors Cylinders Heads Track Pin Assignments Electrical SpecificationPin Signal Descriptions Signal Name Pins Type DescriptionData Inputs/Outputs. This is the 8-bit or Disk Active/Slave Present. This openDMA Request. This signal is used for DMA Controller by -IORD and -IOWR. This signalGround. The device ground signal Interrupt Request. This signal is an activeDevice Power Supply. The device power Symbol Parameter Minimum Maximum UnitsSymbol Parameter Maximum Units Absolute Maximum RatingsDC Characteristics Symbol Parameter 5V ±10% Units Minimum MaximumAccess Read Timing O Access Read TimingAccess Write Timing O Access Write TimingTrue IDE Read/Write Access Timing True IDE Read/Write Access TimingTrue IDE Multiword DMA Read/Write Access Timing True IDE Multiword DMA Read/Write Access TimingATA and True IDE Register Decoding Task File Register SpecificationCS0# CS1# DA02 DA01 DA00 Error Register ATA RegistersFeature Register OperationRead/Write ByteRead/Write Sector Count Default Value Sector Count RegisterRead/Write Sector Number RegisterLogical Block Number bits A07-A00 LBA Addressing Low Cylinder Low RegisterLogical Block Number bits A15-A08 LBA Addressing Cylinder High Register Logical Block Number bits A23-A16 LBA AddressingDrive/Head Register LBA27 LBA26 LBA25 LBA24Status Register Drive Write Fault DWF. Always set toCorrected Data CORR. Always set to Command Register Operation Read/Write ATA Command CodeAlternate Status Register Write Device Control RegisterNIEN Read/Write NWTG NHS3 NHS2 NHS1 NHS0 NDS1 NDS0 Default Value Device Address RegisterATA Command Block and SET Description ATA Command Block and Set DescriptionATA Command Set Class Command Name Registers Used CodeATA Command Set Check Power Mode 98h, E5h Check Power Mode 98h, E5hRegister Executive Drive Diagnostic 90h Executive Drive Diagnostic 90hFormat Track 50h Drive Head Number LBA27-24 Command 50hFormat Track 50h Identify Drive ECh Identify Drive EChWord Data Default Bytes Data Description Address Identify Drive Drive Attribute DataIdentify Drive Drive Attribute Data Identify Drive Drive Attribute Data Idle 97h, E3h Idle 97h, E3hIdle Immediate 95h, E1h Idle Immediate 95h, E1hInitialize Drive Parameters 91h Initialize Drive Parameters 91hRecalibrate 1Xh Drive Command 1XhRecalibrate 1Xh Read Buffer E4h Read Buffer E4hRead DMA C8h Drive Head Number LBA27-24 Command C8hRead DMA C8h Read Multiple C4h Drive Head Number LBA27-24 Command C4hRead Multiple C4h Read Sector 20h, 21h Drive Head Number LBA27-24 Command 20h or 21hRead Sector 20h, 21h Read Long Sectors 22h, 23h Drive Head Number LBA27-24 Command 22h or 23hRead Long Sectors 22h, 23h Read Verify Sectors 40h, 41h Drive Head Number LBA27-24 Command 40h or 41hRead Verify Sectors 40h, 41h Seek 7Xh Drive Head Number LBA27-24 Command 7XhSeek 7Xh Set Features EFh Set Features EFhSet Features’ Attributes Feature OperationSet Multiple Mode C6h Set Multiple Mode C6hSet Sleep Mode 99h, E6h Set Sleep Mode 99h, E6hStandby 96h, E2h Standby 96h, E2hStandby Immediate 94h, E0h Standby Immediate 94h, E0hWrite Buffer E8h Write Buffer E8hWrite DMA CAh Drive Head NumberLBA27-24 Command CAhWrite DMA CAh Write Multiple C5h Drive Head NumberLBA27-24 Command C5hWrite Multiple C5h Write Sectors 30h, 31h Drive Head Number LBA27-24 Command 30h or 31hWrite Sectors 30h, 31h Write Long Sectors 32h, 33h Drive Head Number LBA27-24 Command 32h or 33hWrite Long Sectors 32h, 33h Erase Sectors C0h Drive Head Number LBA27-24 Command C0hErase Sectors C0h Extended Error Codes Extended Error Codes DescriptionRequest Sense 03h Request Sense 03hTranslate Sector 87h Drive Head Number LBA27-24 Command 87hTranslate Sector 87h Wear-Level F5h Wear-Level F5hWrite Multiple w/o Erase CDh Drive Head Number LBA27-24 Command CDhWrite Multiple w/o Erase CDh Write Sectors w/o Erase 38h Drive Head Number LBA27-24 Command 38hWrite Sectors w/o Erase 38h Write Verify 3Ch Drive Head Number LBA27-24 Command 3ChWrite Verify 3Ch Sales and Support Part NumberingPart Numbering Nomenclature Part NumbersStandard Back Label with Front Label Lot Code InformationRelated Documentation Related Documentation